The data were collected using the Melville's SBE911+ system with dual Temperature and
conductivity sensors, a Chelsea/Seatech/Wetlabs CStar fluorometer sensor, Chelsea/Wetlabs
Transmissometer, Biospherical Instruments/LICOR PAR (Irradiance) sensor, and a Sea Bird
SBE043 dissolved oxygen sensor.
Link to NODC Data Form 24-13 for Melville cruise id TUIM14MV CTD Data Submission
File: 8m0509_con_rept.txt
Date: 11/30/2008
Instrument configuration file: F:confilesme0509ctd009.CON
Configuration report for SBE 911plus/917plus CTD
------------------------------------------------
Frequency channels suppressed : 0
Voltage words suppressed : 0
Computer interface : IEEE-488 (GPIB)
Scans to average : 1
Surface PAR voltage added : No
NMEA position data added : Yes
Scan time added : No
1) Frequency 0, Temperature
Serial number : 2359
Calibrated on : 17-FEB-2005odf
G : 4.32814586e-003
H : 6.45643386e-004
I : 2.42576001e-005
J : 2.49241974e-006
F0 : 1000.000
Slope : 1.00000000
Offset : 0.0000
2) Frequency 1, Conductivity
Serial number : 2766
Calibrated on : 02-Aug-05s
G : -1.03722597e+001
H : 1.45612894e+000
I : -7.41726782e-004
J : 1.25838632e-004
CTcor : 3.2500e-006
CPcor : -9.57000000e-008
Slope : 1.00000000
Offset : 0.00000
3) Frequency 2, Pressure, Digiquartz with TC
Serial number : 88907-777
Calibrated on : 12-Jan-2005odf
C1 : -4.516713e+004
C2 : -6.769488e-001
C3 : 1.191515e-002
D1 : 3.702537e-002
D2 : 1.984244e-006
T1 : 3.041228e+001
T2 : -4.880158e-004
T3 : 3.351044e-006
T4 : 1.775127e-008
T5 : 0.000000e+000
Slope : 1.00000000
Offset : 0.00000
AD590M : 1.280490e-002
AD590B : -9.096340e+000
4) Frequency 3, Temperature, 2
Serial number : 2380
Calibrated on : 15-Feb-2005odf
G : 4.34124979e-003
H : 6.42086192e-004
I : 2.39291699e-005
J : 2.28031692e-006
F0 : 1000.000
Slope : 1.00000000
Offset : 0.0000
5) Frequency 4, Conductivity, 2
Serial number : 2765
Calibrated on : 18-Feb-05
G : -1.00375502e+001
H : 1.37695794e+000
I : -9.71475038e-004
J : 1.44271004e-004
CTcor : 3.2500e-006
CPcor : -9.57000000e-008
Slope : 1.00000000
Offset : 0.00000
6) A/D voltage 0, Fluorometer, Chelsea Aqua 3
Serial number : 088191
Calibrated on : 14-Dec-2004
VB : 0.450900
V1 : 2.028900
Vacetone : 0.625500
Scale factor : 1.000000
Slope : 1.000000
Offset : 0.000000
7) A/D voltage 1, Transmissometer, Chelsea/Seatech/Wetlab CStar
Serial number : CST-492DR
Calibrated on : 30-Aug-2001
M : 20.3827
B : -0.1019
Path length : 0.250
8) A/D voltage 2, Oxygen, SBE 43
Serial number : 0454
Calibrated on : 04-Feb-05p
Equation : Owens-Millard
Coefficients for Owens-Millard:
Soc : 4.6170e-001
Boc : 0.0000
Offset : -0.5031
Tcor : -0.0007
Pcor : 1.35e-004
Tau : 0.0
Coefficients for Murphy-Larson:
Soc : 0.00000e+000
Offset : 0.00000e+000
A : 0.00000e+000
B : 0.00000e+000
C : 0.00000e+000
E : 0.00000e+000
Tau : 0.00000e+000
9) A/D voltage 3, Free
10) A/D voltage 4, PAR/Irradiance, Biospherical/Licor
Serial number : 4508
Calibrated on : 11-Feb-2004
M : 1.00000000
B : 0.00000000
Calibration constant : 0.00000001
Multiplier : 1.00000000
Offset : 0.00000000
11) A/D voltage 5, Free
12) A/D voltage 6, Altimeter
Serial number : 9711091
Calibrated on : 2001
Scale factor : 3.000
Offset : 0.000
13) A/D voltage 7, Free