Water column DOC, Chl, PN, PC, PON, POC data from CTD casts
NIWA HAMILTON INORGANIC CHEMISTRY LABORATORY
CLIENT :Scott Nodder LOT NUMBER : 2004000218 CHECKED : MC
NIWA Wellington SF NUMBER : KX 7303 APPROVED : MC
JOB NUMBER : OEBI032 REPORT DATE : 5/10/2006
JOB : TAN 0403
A summary of methods used and detection limits is as follows.
Parameter Description Detection Limit Method
Chlorophyll a(Chla-Av) Acetone pigment extraction, spectrofluorometric measurement. 0 A*10200H
Chlorophyll a(Chla-2) Acetone pigment extraction, spectrofluorometric measurement. 0 A*10200H
Chlorophyll a(Chla-1) Acetone pigment extraction, spectrofluorometric measurement. 0 A*10200H
Chlorophyll a(Chla) Acetone pigment extraction, spectrofluorometric measurement. 0 A*10200H
Dissolved Organic Carbon(DOC) Dissolved Organic Carbon(low level) using TOC analyser 100 APHA5310B
Particulate Nitrogen Filter 1(PN-1) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 2 MAM, 01-1090
Particulate Carbon Filter 2(PC-2) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 1 MAM, 01-1090
Particulate Carbon Filter 1(PC-1) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 1 MAM, 01-1090
Particulate Nitrogen Filter 2(PN-2) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 2 MAM, 01-1090
Particulate Organic Carbon Filter 1(POC-1) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 1 MAM, 01-1090
Particulate Organic Nitrogen Filter 2(PON-2) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 2 MAM, 01-1090
Particulate Organic Nitrogen Filter 1(PON-1) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 2 MAM, 01-1090
Particulate Organic Carbon Filter 2(POC-2) Catalytic comb @900°C, sep, TCD, CE Instruments C/N analyser 1 MAM, 01-1090
Particulate Phosphorus(PartP-2) Acid digest, NH4-N, DRP auto analysis 0.1 Searle
Particulate Phosphorus(PartP-1) Acid digest, NH4-N, DRP auto analysis 0.1 Searle
Particulate Nitrogen(PartN-2) Acid digest, NH4-N, DRP auto analysis 0.1 Searle
Particulate Nitrogen(PartN-1) Acid digest, NH4-N, DRP auto analysis 0.1 Searle
These samples were analysed as received at the laboratory.