Note: Stations 1, 3, and 5 were at a drogue. For stations 2 and 4, the ship moved about 1 kilometer away from the drogue. When station 2 was sampled, the drogue had moved east of it and sampling occurred up-current from the drogue. Tide was ebb --> slack --> flood.
--------------------
Header Information from Sea-Bird SBE19 Data File:
Software Version 1.59
Temperature SN = 504; Conductivity SN = 504
SEACAT PROFILER V2.1e SN 504 05/30/12 13:51:21.934
pressure sensor: serial no = 184805, range = 100 psia, tc = -585
clk = 32767.742 iop = 142 vmain = 11.9 vlith = 5.3
ncasts = 5 samples = 1684 free = 19973 lwait = 0 msec
sample rate = 1 scan every 0.5 seconds
minimum raw conductivity frequency for pump turn on = 0 hertz; pump delay = 30 seconds
battery cutoff = 7.2 volts; number of voltages sampled = 4
cast 0: 05/30 09:50:19 samples 0 to 388 nquan = 7 nvalues = 389
cast 1: 05/30 10:53:36 samples 389 to 774 nquan = 7 nvalues = 386
cast 2: 05/30 11:23:25 samples 775 to 1113 nquan = 7 nvalues = 339
cast 3: 05/30 11:46:51 samples 1114 to 1358 nquan = 7 nvalues = 245
cast 4: 05/30 12:12:29 samples 1359 to 1683 nquan = 7 nvalues = 325
units = specified
name 0 = sigma-t00: Density [sigma-t, Kg/m^3 ]
name 1 = depSM: Depth [salt water, m], lat = 41.00
name 2 = wetStar: Fluorescence, WET Labs WETstar [mg/m^3]
name 3 = sal00: Salinity, Practical [PSU]
name 4 = t090C: Temperature [ITS-90, deg C]
name 5 = timeS: Time, Elapsed [seconds]
name 6 = flag: 0.000e+00
interval = seconds: 0.5; bad_flag = -9.990e-29
sensor 1 = Frequency 0, Temperature; Temp. Sensor ID: 55; SerialNumber: 504;
CalibrationDate: 28-Jan-11
sensor = 2 Frequency 1, Conductivity; Cond. Sensor ID: 3; SerialNumber: 504;
CalibrationDate: 28-Jan-11
sensor = 3 A/D voltage 0, Oxygen Current, Beckman/YSI; Oxygen Sensor ID: 36; SerialNumber: 230238;
CalibrationDate: 21-Mar-2011
sensor = 4 A/D voltage 1, Oxygen Temperature, Beckman/YSI; Oxygen Sensor ID: 39; SerialNumber: 230238;
CalibrationDate: 21-Mar-2011
sensor = 5 A/D voltage 2, Fluorometer, WET Labs WETstar; FluoroWetlabWetstar Sensor ID: 21; SerialNumber: WS3S-166;
CalibrationDate: 23-Feb-2011; ScaleFactor: 15.400
sensor = 6 A/D voltage 3, Free
sensor = 7 Pressure voltage, Pressure, Strain Gauge; Pressure Sensor ID: 49; SerialNumber: 504;
CalibrationDate: 04-Feb-11
datcnv_skipover = 0
-----------