* Sea-Bird SBE 9 Data File:
* FileName = C:\CTD\RR1202\RR1202-00101.hex
* Software Version Seasave V 7.21d
* Temperature SN = 4941
* Conductivity SN = 1879
* Number of Bytes Per Scan = 40
* Number of Voltage Words = 5
* Number of Scans Averaged by the Deck Unit = 1
* System UpLoad Time = Feb 20 2012 06:06:55
* NMEA Latitude = 35 30.41 S
* NMEA Longitude = 037 27.50 E
* NMEA UTC (Time) = Feb 20 2012 06:06:49
* Store Lat/Lon Data = Append to Every Scan
** RR1202 RR1202
** Great Belt 2 Great Belt 2
** Latitude 35o 30.418S
** Longitude 037o 27.521E
** Event # 20120510602
** Great Belt II first CTD cast!!
* System UTC = Feb 20 2012 06:06:55
# interval = seconds: 0.0416667
# start_time = Feb 20 2012 06:06:49 [NMEA time, header]
# <Sensors count="15" >
# <sensor Channel="1" >
# <!-- Frequency 0, Temperature -->
# <TemperatureSensor SensorID="55" >
# <SerialNumber>4941</SerialNumber>
# <CalibrationDate>22-Nov-2011 </CalibrationDate>
# <UseG_J>1</UseG_J>
# <A>4.35132730e-003</A>
# <B>6.42190077e-004</B>
# <C>2.13259987e-005</C>
# <D>1.67064322e-006</D>
# <F0_Old>1000.000</F0_Old>
# <G>4.35113101e-003</G>
# <H>6.41979575e-004</H>
# <I>2.12937606e-005</I>
# <J>1.66918567e-006</J>
# <F0>1000.000</F0>
# <Slope>1.00000000</Slope>
# <Offset>0.0000</Offset>
# </TemperatureSensor>
# </sensor>
# <sensor Channel="2" >
# <!-- Frequency 1, Conductivity -->
# <ConductivitySensor SensorID="3" >
# <SerialNumber>1879</SerialNumber>
# <CalibrationDate>29-Nov-11</CalibrationDate>
# <UseG_J>1</UseG_J>
# <!-- Cell const and series R are applicable only for wide range sensors. -->
# <SeriesR>0.0000</SeriesR>
# <CellConst>2000.0000</CellConst>
# <ConductivityType>0</ConductivityType>
# <Coefficients equation="0" >
# <A>0.00000000e+000</A>
# <B>0.00000000e+000</B>
# <C>0.00000000e+000</C>
# <D>0.00000000e+000</D>
# <M>0.0</M>
# <CPcor>-9.57000000e-008</CPcor>
# </Coefficients>
# <Coefficients equation="1" >
# <G>-4.15590326e+000</G>
# <H>5.39097077e-001</H>
# <I>-7.71437706e-004</I>
# <J>6.72579504e-005</J>
# <CPcor>-9.57000000e-008</CPcor>
# <CTcor>3.2500e-006</CTcor>
# <!-- WBOTC not applicable unless ConductivityType = 1. -->
# <WBOTC>0.00000000e+000</WBOTC>
# </Coefficients>
# <Slope>1.00000000</Slope>
# <Offset>0.00000</Offset>
# </ConductivitySensor>
# </sensor>
# <sensor Channel="3" >
# <!-- Frequency 2, Pressure, Digiquartz with TC -->
# <PressureSensor SensorID="45" >
# <SerialNumber>0401</SerialNumber>
# <CalibrationDate>02-Dec-11</CalibrationDate>
# <C1>-4.588163e+004</C1>
# <C2>1.989810e-001</C2>
# <C3>1.408190e-002</C3>
# <D1>3.950300e-002</D1>
# <D2>0.000000e+000</D2>
# <T1>2.998526e+001</T1>
# <T2>-2.557400e-004</T2>
# <T3>4.268350e-006</T3>
# <T4>1.671990e-009</T4>
# <Slope>0.99997494</Slope>
# <Offset>1.74668</Offset>
# <T5>0.000000e+000</T5>
# <AD590M>1.117000e-002</AD590M>
# <AD590B>-8.668320e+000</AD590B>
# </PressureSensor>
# </sensor>
# <sensor Channel="4" >
# <!-- Frequency 3, Temperature, 2 -->
# <TemperatureSensor SensorID="55" >
# <SerialNumber>4943</SerialNumber>
# <CalibrationDate>22-Nov-2011 </CalibrationDate>
# <UseG_J>1</UseG_J>
# <A>4.37964247e-003</A>
# <B>6.41168176e-004</B>
# <C>2.24890121e-005</C>
# <D>2.09823639e-006</D>
# <F0_Old>1000.000</F0_Old>
# <G>4.37943702e-003</G>
# <H>6.40956250e-004</H>
# <I>2.24569681e-005</I>
# <J>2.09677218e-006</J>
# <F0>1000.000</F0>
# <Slope>1.00000000</Slope>
# <Offset>0.0000</Offset>
# </TemperatureSensor>
# </sensor>
# <sensor Channel="5" >
# <!-- Frequency 4, Conductivity, 2 -->
# <ConductivitySensor SensorID="3" >
# <SerialNumber>1919</SerialNumber>
# <CalibrationDate>29-Nov-11</CalibrationDate>
# <UseG_J>1</UseG_J>
# <!-- Cell const and series R are applicable only for wide range sensors. -->
# <SeriesR>0.0000</SeriesR>
# <CellConst>2000.0000</CellConst>
# <ConductivityType>0</ConductivityType>
# <Coefficients equation="0" >
# <A>0.00000000e+000</A>
# <B>0.00000000e+000</B>
# <C>0.00000000e+000</C>
# <D>0.00000000e+000</D>
# <M>0.0</M>
# <CPcor>-9.57000000e-008</CPcor>
# </Coefficients>
# <Coefficients equation="1" >
# <G>-3.99251720e+000</G>
# <H>5.25640038e-001</H>
# <I>-9.93453447e-004</I>
# <J>7.87689910e-005</J>
# <CPcor>-9.57000000e-008</CPcor>
# <CTcor>3.2500e-006</CTcor>
# <!-- WBOTC not applicable unless ConductivityType = 1. -->
# <WBOTC>0.00000000e+000</WBOTC>
# </Coefficients>
# <Slope>1.00000000</Slope>
# <Offset>0.00000</Offset>
# </ConductivitySensor>
# </sensor>
# <sensor Channel="6" >
# <!-- A/D voltage 0, Fluorometer, Seapoint -->
# <FluoroSeapointSensor SensorID="11" >
# <SerialNumber>SCF 3003</SerialNumber>
# <CalibrationDate></CalibrationDate>
# <!-- The following is an array index, not the actual gain setting. -->
# <GainSetting>2</GainSetting>
# <Offset>0.000</Offset>
# </FluoroSeapointSensor>
# </sensor>
# <sensor Channel="7" >
# <!-- A/D voltage 1, PAR/Irradiance, Biospherical/Licor -->
# <PAR_BiosphericalLicorChelseaSensor SensorID="42" >
# <SerialNumber>4643</SerialNumber>
# <CalibrationDate>14 Dec 2009</CalibrationDate>
# <M>1.00000000</M>
# <B>0.00000000</B>
# <CalibrationConstant>1324503311.26000000</CalibrationConstant>
# <Multiplier>1.00000000</Multiplier>
# <Offset>-1.06070000</Offset>
# </PAR_BiosphericalLicorChelseaSensor>
# </sensor>
# <sensor Channel="8" >
# <!-- A/D voltage 2, Transmissometer, Chelsea/Seatech -->
# <TransChelseaSeatechWetlabCStarSensor SensorID="59" >
# <SerialNumber>CST-1189DR</SerialNumber>
# <CalibrationDate>2008 Nov 3</CalibrationDate>
# <M>19.3070</M>
# <B>-1.1970</B>
# <PathLength>0.250</PathLength>
# </TransChelseaSeatechWetlabCStarSensor>
# </sensor>
# <sensor Channel="9" >
# <!-- A/D voltage 3, Free -->
# </sensor>
# <sensor Channel="10" >
# <!-- A/D voltage 4, Altimeter -->
# <AltimeterSensor SensorID="0" >
# <SerialNumber>41832</SerialNumber>
# <CalibrationDate></CalibrationDate>
# <ScaleFactor>15.000</ScaleFactor>
# <Offset>0.020</Offset>
# </AltimeterSensor>
# </sensor>
# <sensor Channel="11" >
# <!-- A/D voltage 5, Free -->
# </sensor>
# <sensor Channel="12" >
# <!-- A/D voltage 6, Oxygen, SBE 43 -->
# <OxygenSensor SensorID="38" >
# <SerialNumber>1129</SerialNumber>
# <CalibrationDate>23-Nov-11</CalibrationDate>
# <Use2007Equation>1</Use2007Equation>
# <CalibrationCoefficients equation="0" >
# <!-- Coefficients for Owens-Millard equation. -->
# <Boc>0.0000</Boc>
# <Soc>0.0000e+000</Soc>
# <offset>0.0000</offset>
# <Pcor>0.00e+000</Pcor>
# <Tcor>0.0000</Tcor>
# <Tau>0.0</Tau>
# </CalibrationCoefficients>
# <CalibrationCoefficients equation="1" >
# <!-- Coefficients for Sea-Bird equation - SBE calibration in 2007 and later. -->
# <Soc>5.0382e-001</Soc>
# <offset>-0.5242</offset>
# <A>-3.1601e-003</A>
# <B> 1.0886e-004</B>
# <C>-2.1050e-006</C>
# <D0> 2.5826e+000</D0>
# <D1> 1.92634e-004</D1>
# <D2>-4.64803e-002</D2>
# <E> 3.6000e-002</E>
# <Tau20> 2.2400</Tau20>
# <H1>-3.3000e-002</H1>
# <H2> 5.0000e+003</H2>
# <H3> 1.4500e+003</H3>
# </CalibrationCoefficients>
# </OxygenSensor>
# </sensor>
# <sensor Channel="13" >
# <!-- A/D voltage 7, Free -->
# </sensor>
# <sensor Channel="14" >
# <!-- SPAR voltage, Unavailable -->
# </sensor>
# <sensor Channel="15" >
# <!-- SPAR voltage, SPAR/Surface Irradiance -->
# <SPAR_Sensor SensorID="51" >
# <SerialNumber></SerialNumber>
# <CalibrationDate></CalibrationDate>
# <ConversionFactor>0.00000000</ConversionFactor>
# <RatioMultiplier>0.00000000</RatioMultiplier>
# </SPAR_Sensor>
# </sensor>
# </Sensors>
# datcnv_date = Jun 19 2012 09:53:45, 7.21k
# datcnv_in = C:\CTD\rr1202\rr1202-00101.hex C:\CTD\rr1202\rr1202-00101.CON
# datcnv_ox_hysteresis_correction = yes
# datcnv_bottle_scan_range_source = scans marked with bottle confirm bit, 0, 2
# datcnv_scans_per_bottle = 49
# bottlesum_date = Jun 20 2012 07:58:19, 7.21k
# bottlesum_in = C:\ctd\processing\process\rr1202-00101.ros C:\ctd\processing\process\rr1202-00101.CON