Aanderaa Oxygen Optodes
Supplied Name : Aanderaa O2 sensor (model 4175)
Supplied Description :
During the deployment 2 separate ASIS Buoys were deployed, ASIS-1 & ASIS-2, upon each of which 2 SAMIs were attached. Each buoy had 1 SAMI-CO2 attached at 1 meter and 1 SAMI-CO2 attached at 5 meters depth. The SAMI-CO2 sampled on a 30 minute interval and a non-absorbing blank measurement was taken every 3.5 days. PAR was measured by a Li-COR LI-192 underwater quantum sensor (not calibrated). Oxygen data was obtained using a calibrated Aanderaa O2 sensor (model 4175). Both the PAR and O2 sensors were attached to a SAMI-CO2 sensor. There is no pCO2 record at 1 meter on ASIS-2.
Instrument Type
Acronym : AOO
Air-Sea Interaction Spar (ASIS) Buoy
Supplied Name : ASIS-1, ASIS-2
Supplied Description :
During the deployment 2 separate ASIS Buoys were deployed, ASIS-1 & ASIS-2, upon each of which 2 SAMIs were attached. Each buoy had 1 SAMI-CO2 attached at 1 meter and 1 SAMI-CO2 attached at 5 meters depth. The SAMI-CO2 sampled on a 30 minute interval and a non-absorbing blank measurement was taken every 3.5 days. PAR was measured by a Li-COR LI-192 underwater quantum sensor (not calibrated). Oxygen data was obtained using a calibrated Aanderaa O2 sensor (model 4175). Both the PAR and O2 sensors were attached to a SAMI-CO2 sensor. There is no pCO2 record at 1 meter on ASIS-2.
Instrument Type
Acronym : ASIS
LI-COR LI-192 PAR Sensor
Supplied Name : Li-COR LI-192 underwater quantum sensor
Supplied Description :
During the deployment 2 separate ASIS Buoys were deployed, ASIS-1 & ASIS-2, upon each of which 2 SAMIs were attached. Each buoy had 1 SAMI-CO2 attached at 1 meter and 1 SAMI-CO2 attached at 5 meters depth. The SAMI-CO2 sampled on a 30 minute interval and a non-absorbing blank measurement was taken every 3.5 days. PAR was measured by a Li-COR LI-192 underwater quantum sensor (not calibrated). Oxygen data was obtained using a calibrated Aanderaa O2 sensor (model 4175). Both the PAR and O2 sensors were attached to a SAMI-CO2 sensor. There is no pCO2 record at 1 meter on ASIS-2.
Instrument Type
Acronym : LI-COR LI-192 PAR
Generic Description :
The LI-192 Underwater Quantum Sensor (UWQ) measures underwater or atmospheric Photon Flux Density (PPFD) (Photosynthetically Available Radiation from 360 degrees) using a Silicon Photodiode and glass filters encased in a waterproof housing. The LI-192 is cosine corrected and features corrosion resistant, rugged construction for use in freshwater or saltwater and pressures up to 800 psi (5500 kPa, 560 meters depth). Typical output is in um s-1 m-2. The LI-192 uses computer-tailored filter glass to achieve the desired quantum response. Calibration is traceable to NIST. The LI-192 serial numbers begin with UWQ-XXXXX. LI-COR has been producing Underwater Quantum Sensors since 1973.
These LI-192 sensors are typically listed as LI-192SA to designate the 2-pin connector on the base of the housing and require an Underwater Cable (LI-COR part number 2222UWB) to connect to the pins on the Sensor and connect to a data recording device.
The LI-192 differs from the LI-193 primarily in sensitivity and angular response.
193: Sensitivity: Typically 7 uA per 1000 umol s-1 m-2 in water. Azimuth: < ± 3% error over 360° at 90° from normal axis. Angular Response: < ± 4% error up to ± 90° from normal axis.
192: Sensitivity: Typically 4 uA per 1000 umol s-1 m-2 in water. Azimuth: < ± 1% error over 360° at 45° elevation. Cosine Correction: Optimized for underwater and atmospheric use.
(www.licor.com )
pCO2 Sensor
Supplied Name : SAMI-CO2 pCO2
Supplied Description :
During the deployment 2 separate ASIS Buoys were deployed, ASIS-1 & ASIS-2, upon each of which 2 SAMIs were attached. Each buoy had 1 SAMI-CO2 attached at 1 meter and 1 SAMI-CO2 attached at 5 meters depth. The SAMI-CO2 sampled on a 30 minute interval and a non-absorbing blank measurement was taken every 3.5 days. PAR was measured by a Li-COR LI-192 underwater quantum sensor (not calibrated). Oxygen data was obtained using a calibrated Aanderaa O2 sensor (model 4175). Both the PAR and O2 sensors were attached to a SAMI-CO2 sensor. There is no pCO2 record at 1 meter on ASIS-2.
Instrument Type
Generic Description :
A sensor that measures the partial pressure of CO2 in water (pCO2)
Submersible Autonomous Moored Instrument
Supplied Name : SAMI-CO2 pCO2
Supplied Description :
During the deployment 2 separate ASIS Buoys were deployed, ASIS-1 & ASIS-2, upon each of which 2 SAMIs were attached. Each buoy had 1 SAMI-CO2 attached at 1 meter and 1 SAMI-CO2 attached at 5 meters depth. The SAMI-CO2 sampled on a 30 minute interval and a non-absorbing blank measurement was taken every 3.5 days. PAR was measured by a Li-COR LI-192 underwater quantum sensor (not calibrated). Oxygen data was obtained using a calibrated Aanderaa O2 sensor (model 4175). Both the PAR and O2 sensors were attached to a SAMI-CO2 sensor. There is no pCO2 record at 1 meter on ASIS-2.
Instrument Type
Acronym : SAMI
Generic Description :
The Submersible Autonomous Moored Instrument (SAMI) measures and logs levels of dissolved chemicals in sea and fresh water. It is a plastic cylinder about 6 inches wide and 2 feet long that is self-powered and capable of hourly measurements for up to one year. All data collected are logged to an internal memory chip to be downloaded later. SAMI sensors usually are placed a few feet underwater on permanent moorings, while others on floating drifters sample the water wherever the wind and currents carry them. The instruments have been used by researchers around the globe in a variety of studies since 1999. Dr. Mike DeGrandpre, University of Montana, developed the SAMI between 1990 and 1993 during his postdoctoral work at the Woods Hole Oceanographic Institution (Woods Hole, MA, USA). For additional information, see URL: http://www.sunburstsensors.com/ from the manufacturer, Sunburst Sensors, LLC, 1226 West Broadway, Missoula, MT 59802.
Water Temperature Sensor
Supplied Name : SAMI-CO2 pCO2 and Temperature
Supplied Description :
During the deployment 2 separate ASIS Buoys were deployed, ASIS-1 & ASIS-2, upon each of which 2 SAMIs were attached. Each buoy had 1 SAMI-CO2 attached at 1 meter and 1 SAMI-CO2 attached at 5 meters depth. The SAMI-CO2 sampled on a 30 minute interval and a non-absorbing blank measurement was taken every 3.5 days. PAR was measured by a Li-COR LI-192 underwater quantum sensor (not calibrated). Oxygen data was obtained using a calibrated Aanderaa O2 sensor (model 4175). Both the PAR and O2 sensors were attached to a SAMI-CO2 sensor. There is no pCO2 record at 1 meter on ASIS-2.
Instrument Type
Acronym : Water Temp Sensor
Generic Description :
General term for an instrument that measures the temperature of the water with which it is in contact (thermometer).