sample_id |
Unique Identified Code for each sample collected
|
unitless |
sample |
Cruise |
cruise name
|
unitless |
cruise_id |
Cast |
cast number
|
unitless |
cast |
Niskin |
Niskin bottle number
|
unitless |
bottle |
date |
Date (yyyymmdd)
|
unitless |
date |
date_decyr |
Date (decimal year)
|
unitless |
date |
time_UTC |
Timestamp (UTC) hh:mm
|
unitless |
time |
lat |
Latitude; north is positive
|
decimal degrees |
lat |
lon |
Longitude; east is positive
|
decimal degrees |
lon |
Depth |
Sampling depth in meters
|
meters |
depth |
Temp |
CTD temperature
|
degrees celsius |
temp |
CTD_S |
CTD salinity
|
pratical salinity units (PSU) |
sal |
Pressure |
CTD Pressure
|
decibars |
press |
Sigma_theta |
CTD sigma theta (potental density)
|
kilogram/meter^3 |
sigma_t |
Conductivity |
CTD Conductivity
|
Siemens per meter |
cond |
Fluor |
CTD Fluorescence
|
milligram per Liter |
fluor |
Par |
CTD photosynthetically available radiation
|
micro-Einsteins/meter^2/second (uE/m^2/sec) |
PAR |
O2 |
CTD Oxygen
|
millimole per kilogram |
O2 |
beam_trans_CStarTr0 |
CTD beam transmission as percent
|
unitless |
trans |
NO3_NO2 |
Nitrate+Nitrite concentration by flow injection autoanalyzer (Lachat QuikChem 8000)
|
millimole per Liter |
NO3_NO2 |
NO3_NO2_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |
PO4 |
ortho-Phosphate concentration by flow injection autoanalyzer (Lachat QuikChem 8000)
|
millimole per Liter |
PO4 |
PO4_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |
POC_mg_L |
Particulate organic carbon measured by combustion analysis (CEC 440HA). Collected on Glass fiber filter type GF/F (Whatman)
|
milligram per Liter |
POC |
POC_mmol_L |
Particulate organic carbon
|
millimole per Liter |
POC |
POC_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |
PON_mg_L |
Particulate organic nitrogen measured by combustion analysis (CEC 440HA). Collected on Glass fiber filter type GF/F (Whatman)
|
milligram per Liter |
PON |
PON_mmol_L |
Particulate organic nitrogen
|
millimole per Liter |
PON |
PON_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |
DOC |
Dissolved organic carbon concentration by HTCO. Glass fiber filtrate type GF/F (Whatman). Methodological reference is Carlson et al. 2010 DSRII
|
micromolar |
DOC |
DOC_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |
TDN |
Total dissolved nitrogen concentration by HTCO. Glass fiber filtrate type GF/F (Whatman).
|
micromolar |
TDN |
TDN_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |
Bact |
Bacterioplankton abundance by microscopy. Methodological reference: K.G. Porter and Y.S. Feig (1980). The use of DAPI for identifying and counting aquatic microflora. Limnol. Oceanogr 25(5): 943-948.
|
cells per milliliter |
cell_concentration |
Bact_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |
Bact_Prod |
Heterotrophic bacterial production by 3H Leu uptake. Methodological reference: Smith DC & Azam F (1992) A simple economical method for measuring bacterial protein synthesis rates in seawater using 3H-leucine. Mar Microb Food Webs 6: 107_114.
|
picomoles per liter per hour |
leuc_incorp |
Bact_Prod_QF |
Quality Flags (QF): 0 good; 1 unknown; 4 questionable measurement; 8 bad measurement
|
unitless |
q_flag |