CRUISE_ID |
Cruise identifier
|
unitless |
cruise_id |
EVTNBR |
Event number for field sampling deployments, from ship log
|
unitless |
event |
DATE_UTC |
Date of field sampling deployment in UTC time zone; ship time was set at UTC throughout cruise.
|
unitless |
date |
TIME_UTC |
Time in UTC of field sampling deployment; ship time was set at UTC throughout cruise.
|
unitless |
time |
ISO_DateTime_UTC |
Date and time (UTC) of field sampling deployment in ISO 8601 format
|
unitless |
ISO_DateTime_UTC |
JULIAN_DAY |
Julian Day of field sampling deployment.
|
unitless |
julian_day |
EPOCH |
Defined time block during the cruise, #1-3, during which field sampling was conducted.
|
unitless |
time_point |
EPOCH_DAY |
Day within the epoch time block that field sampling was conducted.
|
unitless |
time_point |
LATITUDE |
Ship position when incubation setup water was collected in decimal °N
|
decimal degrees |
lat |
LONGITUDE |
Ship position when incubation setup water was collected in decimal °E
|
decimal degrees |
lon |
PLATFORM |
Sampling system used for incubation setup water collection. TMC CTD = trace metal clean CTD rosette. FISH = towfish
|
unitless |
instrument |
CASTNBR |
Cast number assigned in event log, specific to TMC rosette only. 'na' for 'not applicable' used for towfish deployments.
|
unitless |
cast |
STNNBR |
Station number assigned by EXPORTS program. Note that station A2-C was also the Lagrangian float calibration station. 'na' for 'not applicable' used for towfish deployments.
|
unitless |
station |
BTLNBR |
Identification number of Niskin bottle used for sample collection from the TMC rosette. 'na' for 'not applicable' used for samples collected directly inline from the towfish.
|
unitless |
bottle |
DEPTH |
Depth in meters of incubation setup water collection. Depth of towfish sampling estimated at 2 m in all cases.
|
meters (m) |
depth |
FILTER_SIZE |
Pore size of filter used to process field samples for dissolved trace metals. Note that samples for total dissolvable (TD) metals were all collected unfiltered and filtered through 0.4 um filters prior to analysis. See methods for details.
|
micrometers (um) |
filter_size |
SAMPLE_ID |
Unique identification assigned to each field sample.
|
unitless |
sample |
NO3_NO2_CONC |
Concentrations of dissolved nitrate+nitrite in field samples. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
micromoles per liter (uM) |
NO3_NO2 |
NO3_NO2_STDEV |
Standard deviation of replicate nitrate+nitrite concentration measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
micromoles per liter (uM) |
NO3_NO2 |
NO3_NO2_FLAG |
Quality flag for NO3_NO2.
|
unitless |
q_flag |
PO4_CONC |
Concentrations of dissolved phosphate in field samples. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
micromoles per liter (uM) |
PO4 |
PO4_STDEV |
Standard deviation of replicate phosphate concentration measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
micromoles per liter (uM) |
PO4 |
PO4_FLAG |
Quality flag for PO4.
|
unitless |
q_flag |
SiO4_CONC |
Concentrations of dissolved silicic acid in field samples. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
micromoles per liter (uM) |
SiO4 |
SiO4_STDEV |
Standard deviation of replicate silicate concentration measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
micromoles per liter (uM) |
SiO4 |
SiO4_FLAG |
Quality flag for SiO4.
|
unitless |
q_flag |
NO2_CONC |
Concentrations of dissolved nitrite in field samples. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
micromoles per liter (uM) |
NO2 |
NO2_STDEV |
Standard deviation of replicate dissolved nitrite concentration measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
micromoles per liter (uM) |
NO2 |
NO2_FLAG |
Quality flag for NO2.
|
unitless |
q_flag |
Mn_D_CONC |
Concentrations of dissolved manganese (Mn) in field samples.
|
nanomoles per liter (nmol/L) |
Mn |
Mn_D_STDEV |
Standard deviation of replicate dissolved manganese (Mn) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Mn |
Mn_D_FLAG |
Quality flag for Mn_D_CONC.
|
unitless |
q_flag |
Fe_D_CONC |
Concentrations of total dissolved iron (Fe) in field samples. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
nanomoles per liter (nmol/L) |
Fe |
Fe_D_STDEV |
Standard deviation of replicate total dissolved iron (Fe) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Fe |
Fe_D_FLAG |
Quality flag for Fe_D_CONC.
|
unitless |
q_flag |
Co_D_UV_CONC |
Concentrations of dissolved cobalt (Co) in field samples, measured after UV-oxidation. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
picomoles per liter (pmol/L) |
Co |
Co_D_UV_STDEV |
Standard deviation of replicate dissolved cobalt (Co) measurements in samples that were UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Co |
Co_D_UV_FLAG |
Quality flag for Co_D_UV_CONC.
|
unitless |
q_flag |
Co_D_noUV_CONC |
Concentrations of dissolved cobalt (Co) in field samples; samples were not UV-oxidized prior to measurement. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
picomoles per liter (pmol/L) |
Co |
Co_D_noUV_STDEV |
Standard deviation of replicate dissolved cobalt (Co) measurements in samples that were not UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Co |
Co_D_noUV_FLAG |
Quality flag for Co_D_noUV_CONC.
|
unitless |
q_flag |
Ni_D_UV_CONC |
Concentrations of dissolved nickel (Ni) in field samples, measured after UV-oxidation. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_D_UV_STDEV |
Standard deviation of replicate dissolved nickel (Ni) measurements in samples that were UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_D_UV_FLAG |
Quality flag for Ni_D_UV_CONC.
|
unitless |
q_flag |
Ni_D_noUV_CONC |
Concentrations of dissolved nickel (Ni) in field samples; samples were not UV-oxidized prior to measurement. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_D_noUV_STDEV |
Standard deviation of replicate dissolved nickel (Ni) measurements in samples that were not UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_D_noUV_FLAG |
Quality flag for Ni_D_noUV_CONC.
|
unitless |
q_flag |
Cu_D_UV_CONC |
Concentrations of dissolved copper (Cu) in field samples, measured after UV-oxidation. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_D_UV_STDEV |
Standard deviation of replicate dissolved copper (Cu) measurements in samples that were UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_D_UV_FLAG |
Quality flag for Cu_D_UV_CONC.
|
unitless |
q_flag |
Cu_D_noUV_CONC |
Concentrations of dissolved copper (Cu) in field samples; samples were not UV-oxidized prior to measurement. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_D_noUV_STDEV |
Standard deviation of replicate dissolved copper (Cu) measurements in samples that were not UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_D_noUV_FLAG |
Quality flag for Cu_D_noUV_CONC.
|
unitless |
q_flag |
Zn_D_CONC |
Concentrations of dissolved zinc (Zn) in field samples. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
nanomoles per liter (nmol/L) |
Zn |
Zn_D_STDEV |
Standard deviation of replicate dissolved zinc (Zn) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Zn |
Zn_D_FLAG |
Quality flag for Zn_D_CONC.
|
unitless |
q_flag |
Cd_D_CONC |
Concentrations of dissolved cadmium (Cd) in field samples. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter.
|
picomoles per liter (pmol/L) |
Cd |
Cd_D_STDEV |
Standard deviation of replicate dissolved cadmium (Cd) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Cd |
Cd_D_FLAG |
Quality flag for Cd_D_CONC.
|
unitless |
q_flag |
Pb_D_CONC |
Concentrations of dissolved lead (Pb) in field samples.
|
picomoles per liter (pmol/L) |
Pb |
Pb_D_STDEV |
Standard deviation of replicate dissolved lead (Pb) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Pb |
Pb_D_FLAG |
Quality flag for Pb_D_CONC.
|
unitless |
q_flag |
Mn_TD_CONC |
Concentrations of total dissolvable manganese (TD-Mn) in field samples. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
nanomoles per liter (nmol/L) |
Mn |
Mn_TD_STDEV |
Standard deviation of replicate total dissolvable manganese (TD-Mn) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Mn |
Mn_TD_FLAG |
Quality flag for Mn_TD_CONC.
|
unitless |
q_flag |
Fe_TD_CONC |
Concentrations of total dissolvable iron (TD-Fe) in field samples. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
nanomoles per liter (nmol/L) |
Fe |
Fe_TD_STDEV |
Standard deviation of replicate total dissolvable iron (TD-Fe) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Fe |
Fe_TD_FLAG |
Quality flag for Fe_TD_CONC.
|
unitless |
q_flag |
Co_TD_UV_CONC |
Concentrations of total dissolvable cobalt (TD-Co) in field samples, measured after UV-oxidation. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
picomoles per liter (pmol/L) |
Co |
Co_TD_UV_STDEV |
Standard deviation of replicate total dissolvable cobalt (TD-Co) measurements in samples that were UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Co |
Co_TD_UV_FLAG |
Quality flag for Co_TD_UV_CONC.
|
unitless |
q_flag |
Co_TD_noUV_CONC |
Concentrations of total dissolvable cobalt (TD-Co) in field samples; samples were not UV-oxidized prior to measurement. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
picomoles per liter (pmol/L) |
Co |
Co_TD_noUV_STDEV |
Standard deviation of replicate total dissolvable cobalt (TD-Co) measurements in samples that were not UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Co |
Co_TD_noUV_FLAG |
Quality flag for Co_TD_noUV_CONC.
|
unitless |
q_flag |
Ni_TD_UV_CONC |
Concentrations of total dissolvable nickel (TD-Ni) in field samples, measured after UV-oxidation. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_TD_UV_STDEV |
Standard deviation of replicate total dissolvable nickel (TD-Ni) measurements in samples that were UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_TD_UV_FLAG |
Quality flag for Ni_TD_UV_CONC.
|
unitless |
q_flag |
Ni_TD_noUV_CONC |
Concentrations of total dissolvable nickel (TD-Ni) in field samples; samples were not UV-oxidized prior to measurement. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_TD_noUV_STDEV |
Standard deviation of replicate total dissolvable nickel (TD-Ni) measurements in samples that were not UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Ni |
Ni_TD_noUV_FLAG |
Quality flag for Ni_TD_noUV_CONC.
|
unitless |
q_flag |
Cu_TD_UV_CONC |
Concentrations of total dissolvable copper (TD-Cu) in field samples, measured after UV-oxidation. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_TD_UV_STDEV |
Standard deviation of replicate total dissolvable copper (TD-Cu) measurements in samples that were UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_TD_UV_FLAG |
Quality flag for Cu_TD_UV_CONC.
|
unitless |
q_flag |
Cu_TD_noUV_CONC |
Concentrations of total dissolvable copper (TD-Cu) in field samples; samples were not UV-oxidized prior to measurement. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_TD_noUV_STDEV |
Standard deviation of replicate total dissolvable copper (TD-Cu) measurements in samples that were not UV-oxidized. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Cu |
Cu_TD_noUV_FLAG |
Quality flag for Cu_TD_noUV_CONC.
|
unitless |
q_flag |
Zn_TD_CONC |
Concentrations of total dissolvable zinc (TD-Zn) in field samples. ‘nda’ for ‘no data available’ used when sample was collected but no data has been obtained for this parameter. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
nanomoles per liter (nmol/L) |
Zn |
Zn_TD_STDEV |
Standard deviation of replicate total dissolvable zinc (TD-Zn) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
nanomoles per liter (nmol/L) |
Zn |
Zn_TD_FLAG |
Quality flag for Zn_TD_CONC.
|
unitless |
q_flag |
Cd_TD_CONC |
Concentrations of total dissolvable cadmium (TD-Cd) in field samples. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
picomoles per liter (pmol/L) |
Cd |
Cd_TD_STDEV |
Standard deviation of replicate total dissolvable cadmium (TD-Cd) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Cd |
Cd_TD_FLAG |
Quality flag for Cd_TD_CONC.
|
unitless |
q_flag |
Pb_TD_CONC |
Concentrations of total dissolvable lead (TD-Pb) in field samples. 'na' for 'not applicable’ used when no sample was collected for this parameter.
|
picomoles per liter (pmol/L) |
Pb |
Pb_TD_STDEV |
Standard deviation of replicate total dissolvable lead (TD-Pb) measurements. If only 2 replicates, the difference about the mean was used to calculate error.
|
picomoles per liter (pmol/L) |
Pb |
Pb_TD_FLAG |
Quality flag for Pb_TD_CONC.
|
unitless |
q_flag |