Dataset: Near Edge X-ray Fluorescence Spectroscopy Data for standard organic phosphorus compounds

ValidatedFinal no updates expectedDOI: 10.1575/1912/bco-dmo.762119.1Version 1 (2019-03-13)Dataset Type:experimental

Principal Investigator: Ellery Ingall (Georgia Institute of Technology)

BCO-DMO Data Manager: Shannon Rauch (Woods Hole Oceanographic Institution)


Project: P-NEXFS investigation of the influence of aerosol phosphorus on the Mediterranean Sea (Aerosol P)


Abstract

Near Edge X-ray Fluorescence Spectroscopy Data for standard organic phosphorus compounds.

Methodology: X-ray spectromicroscopy data were collected using an energy dispersive silicon drift detector (Ketek with a 5mm2 sensitive area). A flow of helium was introduced between the X-ray optical hardware and the sample to reduce X-ray backscatter. An in-line monitor stick composed of hydroxyapatite was measured with each sample in order to identify and correct for any potential drift in monochrometer energy calibration that occurred during analyses (de Jonge et al., 2010). Clean areas of Teflon and cellulose acetate filters were examined as blanks and showed negligible background signal. The data for an individual P-NEXFS spectrum were normalized to create a relative intensity value ofapproximately 1 for post-edge area of the spectra (>2160 eV).

Sampling and analytical procedures: Phosphorus compounds were obtained from chemical supply houses. See papers cited below for details.

Instruments: X-ray fluorescence microscope located at beamline 2-ID-B at the Advanced Photon Source, Argonne National Laboratory. The beamline is optimized to examine samples over a 1–4 keV energy range using a focused X-ray beam with a spot size of approximately 60 nanometers squared . The energy was calibrated using a NIST standard reference material SRM2910 calcium hydroxyapatite. The whiteline energy of the standard was set to 2153 eV.

Data processing: P-NEXFS data were normalized to create a relative intensity value of approximately 1 for post-edge area of the spectra.


Related Datasets

No Related Datasets

Related Publications

Results

Longo, A. F., Ingall, E. D., Diaz, J. M., Oakes, M., King, L. E., Nenes, A., … Vine, D. J. (2014). P-NEXFS analysis of aerosol phosphorus delivered to the Mediterranean Sea. Geophysical Research Letters, 41(11), 4043–4049. doi:10.1002/2014gl060555
Methods

De Jonge, M. D., Paterson, D., McNulty, I., Rau, C., Brandes, J. A., & Ingall, E. (2010). An energy and intensity monitor for X-ray absorption near-edge structure measurements. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 619(1-3), 154–156. doi:10.1016/j.nima.2010.01.001