Contributors | Affiliation | Role |
---|---|---|
German, Christopher R. | Woods Hole Oceanographic Institution (WHOI) | Principal Investigator, Contact |
Baumberger, Tamara | National Oceanic and Atmospheric Administration (NOAA-PMEL) | Co-Principal Investigator |
Saito, Mak A. | Woods Hole Oceanographic Institution (WHOI) | Co-Principal Investigator |
Rauch, Shannon | Woods Hole Oceanographic Institution (WHOI BCO-DMO) | BCO-DMO Data Manager |
The hydrothermal plume samples reported here were acquired aboard R/V Melville during two short cruises of opportunity conducted in 2010 (MV 1003) and 2012 (MV 1205). Surveys along the axis of the ridge-crest were conducted using the ship's Seabird 911+ CTD rosette. A combination of tow-yo, vertical casts, and "pogo" stations were employed. An ultra-short baseline (USBL) navigation beacon was attached to the CTD-rosette for all deployments to ensure that we could navigate precisely where all samples and ancillary data were collected, as well as their sample depths.
Samples collected for Helium analyses were processed at the NOAA/PMEL Helium Isotope Laboratory in Newport, OR. The gas and liquid phases of the cold-welded samples were separated using a high-vacuum extraction line. The content of each sealed Cu tube was dropped into an evacuated flask and continuously stirred with a magnetic stirrer during the extraction process. A combined charcoal-LN₂ trap was then used to pump the gas phase into aluminosilicate ampoules during the 15 minute-long gas extraction process. The ampoules were subsequently sealed with a hot flame and stored dry until analysis. Isotope ratios and concentrations of helium were determined using a dual collector, 21 cm radius, sector-type mass spectrometer specially designed for helium isotope analyses. The precision for the helium isotope ratios in seawater samples averaged 0.2% in δ³He, where δ³He is the percentage deviation of the isotopic ratio R=³He/⁴He in the water sample from the atmospheric ³He/⁴He ratio Rₐ= 1.39 x 10⁻⁶: δ³He =((R/Ra)-1)*100 [%].
Methane concentrations were determined at sea. After equilibration, the headspace gas was injected into a SRI 8610C gas chromatograph. Separation of CH₄ was done using a 15 m long Molecular Sieve 5A column and CH₄ concentrations were measured with a flame ionization detector. The measured background seawater CH₄ concentration was 0.4 nM. Sampling and analytical precision, determined through replicate draws, was <2.5% of the measured concentrations or ±0.1 nM, whichever is greater.
Analyses for total dissolvable iron (TDFe) and manganese (TDMn) were conducted on samples selected from Cruise MV1003 (2010) based on shipboard dissolved CH₄ data. Those analyses were conducted using Mg-precipitation, isotope dilution, and inductively coupled plasma mass spectrometry (ICP-MS) following standard methods described elsewhere [Saito and Schneider, 2006; Noble et al., 2008]. Briefly, unfiltered seawater samples were acidified to pH 1.7 using high purity HCl (SeaStar Inc) and then left for 4 months to allow the dissolution of labile metals in weak acid. For each analysis 13.0mL of processed sample was decanted into a centrifuge tube, spiked with ⁵⁷Fe stable isotope and precipitated using a small amount of high-purity ammonia (SeaStar Inc.) then centrifuged for 3 min at 3000 rpm (1460 x g) and decanted. The sample was resuspended in 5% high-purity nitric acid with 1ppm indium (In) and analysis was conducted on an Element 2 ICP-MS using an Aridus desolvator and platinum X-cones. Fe and Mn concentrations were calculated using the ⁵⁷Fe for isotope dilution and In as a recovery tracer [Saito and Schneider, 2006]. Precisions in the measurements were typically better than ±1.0nM for Fe and ±0.2nM for Mn.
All relevant metadata (precision, accuracy, etc.) are published in German et al., 2022 (doi: 10.1029/2021GC010317).
BCO-DMO Processing:
- converted dates to YYYY-MM-DD format;
- created date/time field in ISO8601 format;
- renamed fields to comply with BCO-DMO naming conventions;
- converted latitude and longitude values from degrees and decimal minutes to decimal degrees.
File |
---|
water_column.csv (Comma Separated Values (.csv), 13.00 KB) MD5:51754e31f88541722982f2720ca0e485 Primary data file for dataset ID 871203 |
Parameter | Description | Units |
Cruise_ID | Cruise identifier | unitless |
Date | Sampling date in format YYYY-MM-DD | unitless |
Time_UTC | Sampling time (UTC) in format hh:mm | unitless |
ISO_DateTime_UTC | Sampling date and time (UTC) in format YYYY-MM-DDThh:mmZ | unitless |
Cast | Cast number | unitless |
Bottle | Rosette position | unitless |
Latitude | Latitude of sample (negative values = South) | decimal degrees North |
Longitude | Longitude of sample (negative values = West) | decimal degrees East |
Depth | Sample depth | meters (m) |
delta_3He | He 3/4 anomaly | percent (%) |
CH4 | Dissolved methane (CH4) | nanomolar (nM) |
TDFe | Total dissolvable iron (Fe) | nanomolar (nM) |
TDMn | Total dissolvable manganese (Mn) | nanomolar (nM) |
Dataset-specific Instrument Name | centrifuge |
Generic Instrument Name | Centrifuge |
Generic Instrument Description | A machine with a rapidly rotating container that applies centrifugal force to its contents, typically to separate fluids of different densities (e.g., cream from milk) or liquids from solids. |
Dataset-specific Instrument Name | Seabird 911+ CTD |
Generic Instrument Name | CTD Sea-Bird SBE 911plus |
Generic Instrument Description | The Sea-Bird SBE 911 plus is a type of CTD instrument package for continuous measurement of conductivity, temperature and pressure. The SBE 911 plus includes the SBE 9plus Underwater Unit and the SBE 11plus Deck Unit (for real-time readout using conductive wire) for deployment from a vessel. The combination of the SBE 9 plus and SBE 11 plus is called a SBE 911 plus. The SBE 9 plus uses Sea-Bird's standard modular temperature and conductivity sensors (SBE 3 plus and SBE 4). The SBE 9 plus CTD can be configured with up to eight auxiliary sensors to measure other parameters including dissolved oxygen, pH, turbidity, fluorescence, light (PAR), light transmission, etc.). more information from Sea-Bird Electronics |
Dataset-specific Instrument Name | SRI 8610C gas chromatograph |
Generic Instrument Name | Gas Chromatograph |
Generic Instrument Description | Instrument separating gases, volatile substances, or substances dissolved in a volatile solvent by transporting an inert gas through a column packed with a sorbent to a detector for assay. (from SeaDataNet, BODC) |
Dataset-specific Instrument Name | Element 2 ICP-MS |
Generic Instrument Name | Inductively Coupled Plasma Mass Spectrometer |
Generic Instrument Description | An ICP Mass Spec is an instrument that passes nebulized samples into an inductively-coupled gas plasma (8-10000 K) where they are atomized and ionized. Ions of specific mass-to-charge ratios are quantified in a quadrupole mass spectrometer. |
Dataset-specific Instrument Name | |
Generic Instrument Name | Mass Spectrometer |
Dataset-specific Description | A dual collector, 21 cm radius, sector-type mass spectrometer specially designed for helium isotope analyses |
Generic Instrument Description | General term for instruments used to measure the mass-to-charge ratio of ions; generally used to find the composition of a sample by generating a mass spectrum representing the masses of sample components. |
Website | |
Platform | R/V Melville |
Start Date | 2012-04-20 |
End Date | 2012-04-30 |
Description | See more information from the Rolling Deck to Repository (R2R) at https://www.rvdata.us/search/cruise/MV1205 and from NOAA at https://oceanexplorer.noaa.gov/explorations/12chile/background/backgroun... |
Website | |
Platform | R/V Melville |
Start Date | 2010-02-24 |
End Date | 2010-03-17 |
Description | See additional information from the Rolling Deck to Repository (R2R) at https://www.rvdata.us/search/cruise/MV1003 and from NOAA at https://oceanexplorer.noaa.gov/explorations/10chile/ |
The first INSPIRE (INternational Southeast Pacific Investigation of Reducing Environments) expedition took place from February 24 to March 17, 2010. During 22 days aboard the research vessel (R/V) Melville, members of the INSPIRE: Chile 2010 expedition set out to explore four largely unknown regions of our planet, in search of missing links in our understanding of biology, geology, and chemistry within the deep ocean. Through hours of conductivity, temperature, depth (CTD) work - comprising 33 separate deployments, 26 bouts of multicoring, and 10 trawls - we sampled at depths between 350 and 6100 meters (up to 18,000 feet).
The 2012 INSPIRE expedition took place from April 20-30, 2012. During the 10-day cruise on the R/V Melville, we probed for strange new biological life forms, communities, and ecosystems dependent on as-yet-unknown conditions. Members of the INSPIRE team used an autonomous underwater vehicle (outfitted with cameras and chemical sensors) called Sentry - in combination with instrumentation to measure conductivity, temperature, depth (CTD), a multicorer, and a towed camera system - to locate and characterize heretofore unknown and some barely known ecosystems.
Read more about both expeditions:
https://oceanexplorer.noaa.gov/explorations/10chile/
https://oceanexplorer.noaa.gov/explorations/12chile/welcome.html
Funding Source | Award |
---|---|
NOAA Ocean Exploration |