Total chlorophyll a pigment. See dataset for units of measurement; often reported in: milligrams per cubic meter (mg/m3); micrograms/liter (ug/L); nanograms/liter (ng/L).
CAUTION Within JGOFS MERGED water column products: this parameter is derived from HPLC methodology and the units are nanograms/liter; however; this parameter name is also used for a variety of water and nonwater column sampling; derived via the fluorometric method; units will also vary.
Calibrated chlorophyll-a; Corrected fluorometric chlorophyll-a concentrations (chl_corr derived above) were calibrated to chlorophyll-a concentrations measured by HPLC of bottle samples collected during concurrent Bermuda Atlantic Time-series Study cruises (available at http://www.bco-dmo.org/project/2124 or http://bats.bios.edu).
Linear regression yields the relationship:
chl_cal [u=ug/L] = chl [ug/L] * 0.4756 + 0.0064; R2 = 0.92.