Instrument: Water Quality Multiprobe

Acronym: Water Quality Multiprobe
External Identifier:

Description

An instrument which measures multiple water quality parameters based on the sensor configuration.


Dataset NamePI-Supplied DescriptionPI-Supplied Name
Autonomously collected pH data from Narragansett Bay in 2022 and 2023The Conanicut Hydrocat 620 and Potowomut Hydrocat 720 sensors were equipped with Seabird Hydrocat-EP CTD sensors (model number# HC-EP.1011S), equipped with a Seabird Hydrocat-EP pH Module (model#802532). Hydrocat-EPs collected multiple parameters including temperature, salinity, pH, dissolved oxygen.  Seabird Hydrocat-EP pH Module (model#802532)
Seawater chemistry and benthic metabolic rates as a function of coral cover from a mesocosm experiment conducted at the Bermuda Institute of Ocean Sciences in August 2012A YSI was used to monitor in situ temperature (accuracy ± 0.15°C), salinity (accuracy ± 1%), DO_mg (accuracy ± 0.2 mg/L), and DO_% (accuracy ± 2%), and pH (accuracy ± 0.2). YSI 556 Handheld Multiprobe Sensor
Seawater chemistry and benthic metabolic rates as a function of coral cover from a mesocosm experiment conducted at the Hawaii Institute of Marine Biology in June 2016YSI Handheld Multiparameter Instruments were used to monitor in situ temperature (accuracy ± 0.2°C), salinity (accuracy ± 1%), DO_mg (accuracy ± 0.2 mg/L), and DO_% (accuracy ± 2%), and pH (accuracy ± 0.2). YSI Professional Plus (Pro Plus) Handheld Multiparameter
Carbon and nitrogen data from kelp determined during seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp speciesmeasurements of temperature and salinity recorded with a handheld meter (YSI) handheld meter (YSI)
Carbonate chemistry and light data from bottle samples A YSI 556 Handheld Multiparameter Instrument was used to measure in situ temperature (accuracy ± 0.15°C), salinity (accuracy ± 1%), DO_mg (accuracy ± 2%), and DO_% (accuracy ± 2%). YSI 556 Handheld Multiparameter Instrument
Accession numbers and images of coral samples taken in the Florida Keys during 2013 (Coral Microbial Relationships project)Temperature, DO, and pH measured just above the coral colony and at surface. EXO Water Quality Sonde
Data describing O2, pH, temperature, and salinity in a light chamber (ECHOES project)Multi-sensor data sonde (MS5; Hydrolab) multi-sensor data sonde
Data describing O2, pH, temperature, and salinity from a data sonde located within the water column near an eddy covariance instrument (ECHOES project)Multi-sensor data sonde (MS5; Hydrolab) multi-sensor data sonde
Diel carbonate and nutrient chemistry reported for different benthic reef communities under ambient and acidified conditions during summer and winterYSI Handheld Multiparameter Instruments were used to monitor in situ temperature (accuracy ± 0.2°C), salinity (accuracy ± 1%), DO_mg (accuracy ± 0.2 mg/L), and DO_% (accuracy ± 2%), and pH (accuracy ± 0.2). YSI Professional Plus (Pro Plus) Handheld Multiparameter
Discrete carbonate data from Narragansett Bay in 2022 and 2023Temperature and salinity in the discrete carbonate data were measured with the Seabird instruments (analogous sites in the autonomous dataset).  Seabird Hydrocat-EP CTD sensors (model number# HC-EP.1011S), equipped with a Seabird Hydrocat-EP pH Module (model#802532). Hydrocat-EPs collected multiple parameters including temperature, salinity, pH, dissolved oxygen.  Seabird Hydrocat-EP pH Module (model#802532)
Species counts, site-level information and environmental context sampled near Port Fourchon, Louisiana from September 23 - 29, 2022. Salinity and temperature were measured using a YSI probe. Model#: 30M-10 FT YSI probe. Model#: 30M-10 F
Results from feeding assays conducted as part of seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp speciesmeasurements of temperature and salinity recorded with a handheld meter (YSI) handheld meter (YSI)
Water quality data and Olympia oyster abundance counts from depth-specific sampling collected by boat in Fidalgo Bay, WA, during July 2017A Hach Environmental Company HydroLab DS5 water quality multiprobe is designed for in-situ measurements. We used the Hach Temperature and Hach Conductivity sensors to measure temperature (°C) and salinity. The Hach Temperature sensor is factory set and did not require re-calibration. We performed a two-point calibration on the Hach Conductivity sensor using YSI conductivity calibrator solution before each days use. HydroLab DS5 (Hach Environmental Co.)
Eddy covariance proton and oxygen, DIC, TA flux data collected at Woods Hole Oceanographic Institution in 2014 (ECHOES project)Multi-sensor data sonde (MS5; Hydrolab) multi-sensor data sonde
Spatial surveys of carbonate chemistry in Heron Reef, Great Barrier Reef, AustraliaThe instrument was used to measure in situ temperature (±0.2°C), salinity (± 1%), and DO (both mg/L and %; ± 2%). YSI Professional Plus handheld multi-parameter instrument (YSI 6600 V2)
Salinity and temperature data collected at the MBL dock in Woods Hole, MA, USA in 2012 (Mnemiopsis feeding in turbulence project)The temperature and salinity were measured using a Hach Hydrolab MiniSonde 4a. Hach Hydrolab MiniSonde 4a
Non-oyster species counts and sizes from caged and non-caged juvenile oyster experiment using two cohorts from Apalachicola Bay and Ocholckonee Bay stockUsed a YSI probe to get dissolved oxygen, temperature, salinity and pH at the surface and at the bottom. YSI
The status of juvenile oysters from a caged and non-caged recruitment experiments using two cohorts from Apalachicola Bay and Ocholckonee Bay stock, 2013-2016 and 2019Used a YSI probe to get dissolved oxygen, temperature, salinity and pH at the surface and at the bottom. YSI
Kelp growth data from seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp species measurements of temperature and salinity recorded with a handheld meter (YSI) handheld meter (YSI)
Monthly cross-shore transects of biogeochemical properties in La Jolla, CAThe instrument was used to measure in situ temperature (±0.2°C), salinity (± 1%), and DO (both mg/L and %; ± 2%). YSI Professional Plus handheld multi-parameter instrument (YSI 6600 V2)
Attributes of 36 tide pools measured in the light and dark at John Brown’s Beach, Sitka, Alaska, USA during 2018-2020Salinity, dissolved Oxygen, and temperature were measured with a ProDSS Multiparameter Water Quality Meter (YSI, Yellow Springs, Ohio, USA). ProDSS Multiparameter Water Quality Meter
Attributes of 36 tide pools measured in the light and dark at John Brown’s Beach, Sitka, Alaska, USA during 2018-2020pH was measured with a Hanna Instruments 9829 Multiparameter Meter (Hanna Instruments, Smithfield, Rhode Island, USA), which was calibrated with a multipoint calibration to a Tris standard (Marine Physical Laboratory, Scripps Institution of Oceanography, La Jolla, California, USA). Hanna Instruments 9829 Multiparameter Meter
Data describing oxygen, temperature, and salinity in Marsh Pond in Massachusetts from 2014.Used to take water quality measurements; temperature, salinity, and oxygen YSI Exo2 water quality sonde
pH and total alkalinity measurements of treatment tub seawater during lab experiments conducted in spring 2022. Handheld meter (YSI Incorporated, Yellow Springs, OH, USA) for salnity and temperature, and salinity was adjusted with deionized (DI) water as needed Handheld meter (YSI Incorporated, Yellow Springs, OH, USA
Temperature, pH, DO, and salinity data from Mumford Cove, Connecticut, USA from 2015-2022Took data on temperature, pH, DO, and salinity Eureka Manta Sub2 probe
Otolith microstructure of young-of-year Atlantic silversides (Menidia menidia) from Mumford Cove during 2015Eureka Manta Sub2 monitoring probe, deployed 0.5m above bottom in Mumford Cove, CT Eureka Manta Sub2 monitoring probe
Surveys of inhabitants on the intertidal and subtidal oyster reef in Apalachicola Bay and Ocholckonee Bay, FL, 2013-2019Used to measure dissolved oxygen, temperature, salinity and pH. YSI Pro 2030
Environmental sensor data collected in Palau marine lakes from small boats, 2011-2015Multiparameter water quality sonde measuring Temperature, Conductivity, Depth, pH, Oxygen Reduction Potential (ORP), Dissolved Oxygen (Clark Cell), Turbidity. Hydrolab Quanta Multi-Probe Meter multiparameter water quality sonde
Porites asteroides and Diploria labyrinthiformis calcification from coral colony buoyant weights measured at Hog and Crescent Reef, Bermuda between 2010 and 2012 (BEACON project)A YSI 556 Handheld Multiparameter Instrument was used to measure in situ temperature (accuracy ± 0.15°C), and salinity (accuracy ± 1%). YSI 556 Handheld Multiparameter Instrument
Salinity tolerance of oysters without acclimation in lab conditions: Water QualityWater temperature was measured using an aquarium thermometer or YSI ProDSS multiprobe.Dissolved oxygen concentrations and saturation, and pH were measured using a YSI ProDSS multiprobe. YSI ProDSS sensors were calibrated at least weekly. YSI ProDSS multiprobe
Carbon export from San Dieguito Lagoon from samples for seawater carbonate biogeochemistry between April 2014 and January 2015YSI Handheld Multiparameter Instrument was used to measure in situ temperature (accuracy ± 0.15°C), salinity (accuracy ± 1%), and DO% (accuracy ± 2%). Water Quality Multiprobe
Site descriptions and physical environmental conditions in coral microbiomes in the Florida Keys during 2013 (Coral Microbial Relationships project)Temperature, DO, and pH measured just above the coral colony and at surface. EXO Water Quality Sonde
Average sediment grain size at in- and out-flow at Carlsbad Desalination Plant, Southern California,2014-2016 (Effluent Impacts on Coastal Ecology project)YSI 85 Handheld Oxygen, Conductivity, Salinity, mg/L C and Temperature System
Spatial surveys of carbonate chemistry conducted in Kaneohe Bay, Hawaii from small boats during 2015 to 2017YSI Handheld Multiparameter Instruments were used to measure in situ temperature (accuracy ± 0.15°C), salinity (accuracy ± 1%), DO_mg (accuracy ± 2%), and DO_% (accuracy ± 2%). Instrument models used: October 2015: YSI 6600 V2; June 2016, November 2016: YSI Professional Plus; February 2017: YSI 556. Handheld YSI multi probes
Time series observations: hydrography, nutrients, and microbial, phytoplankton and zooplankton communities from the Skidaway River Estuary on the southeastern Atlantic coast of Georgia from 1986-2011 (SRiMP project)Multi-Probe MANTA-2 From September 2011 until present, a multi-probe MANTA-2 (EUREKA Environmental Engineering, Austin, TX, USA) has been included to measure depths profiles of temperature, salinity, pH, conductivity, turbidity, in situ chlorophyll fluorescence and DO. Multi-Probe MANTA-2
Oysters size and presence or absence of disease at intertidal and subtidal reefs in Apalachicola Bay and Ocholckonee Bays, FL, July-August 2016Used to measure dissolved oxygen, temperature, salinity and pH. YSI Pro 2030
Organism sizes on oyster reef quadrats from surveys in Apalachicola Bay and Ocholckonee Bay, FL, 2013-2019Used to measure dissolved oxygen, temperature, salinity and pH. YSI Pro 2030
T. rotula microbiome global sampleA YSI instrument measured SST and salinity. YSI
Water and oxygen metabolism flux data from two tidal creeks on Plum Island, Massachusetts during 2012.Used to take water quality measurements YSI 6-series water quality datalogging sonde
Water chemistry analysis of samples collected at the Carlsbad Desalination Plant along the coast of Southern California in 2014-2016 (Effluent Impacts on Coastal Ecology project)YSI 85 Handheld Oxygen, Conductivity, Salinity, mg/L C and Temperature System
Water quality data from surveys, experiments and the NERR data sonde, sub-tropical estuarine waters, subtidal and intertidal in Apalachicola Bay and Ocholckonee Bay, Florida, 2013-2019Used to measure dissolved oxygen, temperature, salinity and pH. YSI Pro 2030