Instrument: Aerosol Sampler

Acronym:
External Identifier: skos:broadMatch: http://vocab.nerc.ac.uk/collection/L05/current/13/

Description

A device that collects a sample of aerosol (dry particles or liquid droplets) from the atmosphere.


Dataset NamePI-Supplied DescriptionPI-Supplied Name
Be-7 from aerosol samples from the Arctic collected on RV Polarstern cruise ARK-XXVI/3 from Tromso, Norway to Bremerhaven, Germany in 2011 (Be-7 Tracer Method project)Aerosol samples were collected using a TischTE-5170-VBL high volume aerosol sampler, modified to collect 12 replicate aerosol samples on 47mm open-face filter holders loaded with acid-washed Whatman-41 ashless filters for trace element analysis. TischTE-5170-VBL
Trace metal aerosol data from R/V Polarstern cruise ARK-XXVI-3 from Tromso, Norway to Bremerhaven, Germany in 2011 (Be-7 Tracer Method project)Tisch Environmental TSP TE5170V
Concentrations of the rare earth elements (REE) and Thorium-232 (232Th) in glacial dust from the northern Gulf of Alaska regionSize-fractionated samples were collected using a Tisch Volumetric Flow Controlled (VFC) high-volume sampler (Tisch Environmental, TE-5170V- BL) outfitted with a Cascade impactor. Tisch Environmental, TE-5170V- BL
Aerosol trace element concentrations in the Florida Keys National Marine Sanctuary from 2014-2015 (Vibrio-dust deposition project)A device that collects a sample of aerosol (dry particles) from the atmosphere. PI supplied instrument name: Aerosol Sampler Dataset-specific description: High-volume Tish Environmental (model 5170-VBL) aerosol sampler. Aerosol_Sampler
Aerosol aluminum measurements from Tudor Hill, Bermuda collected November 2018 to March 2020 as part of the Bermuda Atlantic Iron Timeseries projectA high-volume bulk aerosol sampler was custom built at the University of Miami Rosenstiel School of Marine, Atmospheric, and Earth Science. Custom-built high-volume bulk aerosol sampler (University of Miami RSMAS)
Atmospheric concentrations of aerosol iron from samples collected at Tudor Hill Bermuda between November 2018 and March 2020. A high-volume air sampler that was custom-built (University of Miami Rosenstiel School of Marine, Atmospheric, and Earth Science) was used to collect aerosols on acid-cleaned filters. High-volume bulk aerosol sampler
Stable isotopic composition of total, deionized-water-soluble, and dilute-acetic-acid-soluble aerosol iron from analysis of composite aerosol samples collected at Tudor Hill, Bermuda between Nov 2018 and March 2020high-volume air sampler
Seawater concentrations of dissolved and total Th-232 and Th-230 collected from the R/V Atlantic Explorer (AE1410) cruise from Barbados to Bermuda during 2014Tisch Environmental PM10 aerosol sampler (TE-6070), using 20 cm x 25 cm Whatman41 filter sheets.
Beryllium-7 Aerosol Concentration from USCGC Healy cruise HLY1502 in the Canada and Makarov Basins of the Arctic Ocean from August to October 2015 (US GEOTRACES Arctic)Aerosol samples were obtained with a Tisch TE-5170V-BL high volume aerosol sampler. Tisch TE-5170V-BL
Coarse aerosol iron (Fe) collected on the US GEOTRACES Arctic cruise (HLY1502, GN01) from August to October 2015Aerosol samples were collected by a MICRO ORIFiCE UNIFORM DEPOSIT IMPACTOR (MOUDI) (MSP Corporation, MN, USA) which was installed on the forward rail of Healy's flying bridge. Micro-orifice uniform deposit impactor (MOUDI)
Fine aerosol iron (Fe) collected on the US GEOTRACES Arctic cruise (HLY1502, GN01) from August to October 2015Aerosol samples were collected by a MICRO ORIFiCE UNIFORM DEPOSIT IMPACTOR (MOUDI) (MSP Corporation, MN, USA) which was installed on the forward rail of Healy's flying bridge. Micro-orifice uniform deposit impactor (MOUDI)
Mercury and methylmercury concentrations in aerosols from the US GEOTRACES Arctic cruise (HLY1502, GN01) from August to October 2015high-volume aerosol samplers
Aerosol Nitrate (NO3) from samples collected on the US GEOTRACES Arctic cruise (HLY1502) from August to October 2015Tisch TE-5170V-BL high volume aerosol sampler
Soluble Ionic Species (Coarse) in aerosols collected on the US GEOTRACES Arctic cruise (HLY1502, GN01) from August to October 2015 from from August to October 2015Aerosol samples were collected by a MICRO ORIFiCE UNIFORM DEPOSIT IMPACTOR (MOUDI) (MSP Corporation, MN, USA) which was installed on the forward rail of Healy's flying bridge. Micro-orifice uniform deposit impactor (MOUDI)
Soluble Ionic Species (Fine) in aerosols collected on the US GEOTRACES Arctic cruise (HLY1502, GN01) from August to October 2015Aerosol samples were collected by a MICRO ORIFiCE UNIFORM DEPOSIT IMPACTOR (MOUDI) (MSP Corporation, MN, USA) which was installed on the forward rail of Healy's flying bridge. Micro-orifice uniform deposit impactor (MOUDI)
Atmospheric total gaseous mercury from the US GEOTRACES Arctic cruise (HLY1502, GN01) from August to October 2015low-volume aerosol sampler
Particulate & dissolved Po-210 & Pb-210 in seawater, snow, melt ponds, ice core, ice-rafted sediments, and aerosols from the US GEOTRACES Arctic cruise (HLY1502) on USCGC Healy from August to October 2015high-volume aerosol samplers
Aerosol Selenium data from the US GEOTRACES Arctic cruise (HLY1502, GN01) from August to October 2015High-volume aerosol sampler (Tisch 5170V-BL)
Concentrations of aerosol trace elements collected from bulk aerosol samples on the 2015 US GEOTRACES Western Arctic Transect cruise on USCGC Healy (HLY1502) from August to October 2015Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL) were used for sample collection. Tisch Environmental high-volume aerosol samplers
Concentrations of ultrapure water soluble aerosol trace elements collected from bulk aerosol samples on the 2015 US GEOTRACES Western Arctic Transect on USCGC Healy (HLY1502) August to October 2015Bulk aerosol samples for multiple trace element analyses were collected using one of five Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL).  Tisch Environmental high-volume aerosol samplers
Activities of 210Po and 210Pb in aerosol samples collected on Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Bulk aerosol samples were collected on 12-replicate acid-washed, 47-mm Whatman 41 (W41) ashless filter discs mounted in Advantec-MFS polypropylene open-face filter holders
Activities of 210Po and 210Pb in aerosol samples collected on Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from October to November 2018Bulk aerosol samples were collected on 12-replicate acid-washed, 47-mm Whatman 41 (W41) ashless filter discs mounted in Advantec-MFS polypropylene open-face filter holders
Aerosol lead (Pb) and Pb isotopes from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018See Morton et al. 2013 High-volume aerosol sampling system onboard at sea
Aerosol lead (Pb) and Pb isotopes from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from Oct-Nov 2018See Morton et al. 2013 High-volume aerosol sampling system onboard at sea
Aerosol and seawater beryllium-7 concentrations from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Aerosol samples were obtained with a Tisch TE-5170V-BL high volume aerosol sampler, modified to collect 12 replicate samples on acid-washed 47mm diameter Whatman-41 (W-41) filters, using procedures of the US GEOTRACES aerosol program. Tisch TE-5170V-BL high volume aerosol sampler
Aerosol and seawater beryllium-7 concentrations from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from October to November 2018Aerosol samples were obtained with a Tisch TE-5170V-BL high volume aerosol sampler, modified to collect 12 replicate samples on acid-washed 47mm diameter Whatman-41 (W-41) filters, using procedures of the US GEOTRACES aerosol program. Tisch TE-5170V-BL high volume aerosol sampler
Concentrations and stable isotopes of total and deionized water-soluble Fe, Zn, and Cd bulk aerosols and Fe concentrations and stable isotopes of coarse and fine aerosols from Leg 1 of the US GEOTRACES PMT cruise (GP15, RR1814) from Sept to Oct 2018High-volume aerosol sampler (Tisch Environmental, model 5170V-BL)
Concentrations and stable isotopes of total and deionized water-soluble Fe, Zn, and Cd bulk aerosols and Fe concentrations and stable isotopes of coarse and fine aerosols from Leg 2 of the US GEOTRACES PMT cruise (GP15, RR1815) from Oct to Nov 2018High-volume aerosol sampler (Tisch Environmental, model 5170V-BL)
Concentrations of deionized water-soluble aerosol trace elements collected from bulk aerosol samples on Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from Sept-Oct 2018Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL)
Concentrations of deionized water-soluble aerosol trace elements collected from bulk aerosol samples on Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES PMT cruise (GP15, RR1815) on R/V Roger Revelle from Oct-Nov 2018Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL)
Atmospheric & gaseous mercury from aerosol samples collected using high volume and low volume sampling systems on Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES PMT cruise (GP15, RR1814) on R/V Roger Revelle from Sept-Oct 2018Tisch Environmental, model 5170V-BL
Atmospheric & gaseous mercury from aerosol samples collected using high volume and low volume sampling systems on Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES PMT cruise (GP15, RR1815) on R/V Roger Revelle from Oct-Nov 2018Tisch Environmental, model 5170V-BL
Concentrations of deionized water-soluble aerosol major ions from bulk aerosol samples collected on Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from Sept-Oct 2018Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL)
Concentrations of deionized water-soluble aerosol major ions from bulk aerosol samples collected on Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES PMT cruise (GP15, RR1815) on R/V Roger Revelle from Oct-Nov 2018Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL)
Total aerosol trace elements from bulk aerosol samples collected on Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from September to October 2018Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL)
Total aerosol trace elements from bulk aerosol samples collected on Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from Oct-Nov 2018Tisch Environmental high-volume (~1 m3 air min-1) aerosol samplers (model 5170V-BL)
Acetic acid leachable trace metals from bulk aerosol samples collected during the US GEOTRACES EPZT section cruise (R/V Thomas G. Thompson TN303) in the Eastern Tropical Pacific from October to December 2013Tisch Environmental TSP TE5170V
Beryllium-7 aerosol concentration from GEOTRACES Peru-Tahiti section on R/V Thomas G. Thompson cruise TN303 from October to December 2013Aerosol samples were obtained with a Tisch TE-5170V-BL high volume aerosol sampler, modified to collect 12 replicate samples on acid-washed 47 mm diameter Whatman-41 (W-41) filters, using procedures of the US GEOTRACES aerosol program. Tisch TE-5170V-BL high volume aerosol sampler
DI water soluble trace element concentrations from bulk aerosol samples collected during the 2013 US GEOTRACES EPZT section cruise (R/V Thomas G. Thompson TN303) in the Eastern Tropical PacificTisch Environmental TSP TE5170V
Aerosols analyzed for Pb-210 collected on R/V Thomas G. Thompson cruise TN303 in the Eastern Tropical Pacific from October to December 2013 (U.S. GEOTRACES EPZT project)Aerosol samples (for bulk aerosols using a Tisch Environmental TSP TE-5170V-BL, 47mm Whatman 41 filters and size-fractionated aerosols using a Tisch TE-235 5-stage slotted impactor with Whatman 41 slotted substrates) by the Florida State University group (FSU). Refer to: https://tisch-env.com/wp-content/uploads/2015/07/TE-5170V-BL-Manual.pdf Tisch Environmental TSP TE-5170V-BL
Nitrate (NO3) aerosol isotopes from the U.S. GEOTRACES EPZT cruise TN303 on R/V Thomas G. Thompson in the Eastern Tropical Pacific from October to December 2013Samples were collected using Florida State University's high volume aerosol sampler (Tisch Environmental TSP TE5170V). Samples were collected at the rate of 1 cubic meter per minute on Whatman 41, 47 mm discs (glass fiber; GF) and were pre-combusted before deployment. Tisch Environmental TSP TE5170V
Total particulate trace element concentrations from bulk aerosol samples collected during the US GEOTRACES EPZT section cruise (R/V Thomas G. Thompson TN303) in the Eastern Tropical Pacific from October to December 2013Tisch Environmental TSP TE5170V
Aerosol and seawater beryllium-7 concentrations from the US GEOTRACES GP17-OCE cruise on R/V Roger Revelle (RR2214) in the South Pacific and Southern Oceans from December 2022 to January 2023Tisch TE-5170V-BL high volume aerosol sampler
Aerosol and seawater beryllium-7 concentrations from the French GEOTRACES GS02 SWINGS cruise aboard R/V Marion-Dufresne (MD229) from January to March 2021Tisch TE-5170V-BL high volume aerosol sampler
Spectral magnitude data for 0.0008 ppm bands from aerosol water soluble organic matter 1H NMR spectra from R/V Knorr GEOTRACES cruises KN199-04 and KN204-01 in the Subtropical northern Atlantic Ocean in 2010 and 2011
Organic carbon and water soluble organic carbon atmospheric loadings from aerosol samples from R/V Knorr GEOTRACES cruises KN199-04 and KN204-01 in the Subtropical northern Atlantic Ocean in 2010 and 2011
m/z and peak intensity data for the molecular formulas assigned to aerosol water soluble organic matter samples run by ESI FTICR MS from R/V Knorr GEOTRACES cruises KN199-04 and KN204-01 in the Subtropical northern Atlantic Ocean in 2010 and 2011
DI water soluble aerosol trace elements from R/V Knorr cruises KN199-04 and KN204-01 in the Subtropical northern Atlantic Ocean from 2010-2011 (U.S. GEOTRACES NAT project)The Florida State University high volume aerosol sampler (Tisch Environmental TSP TE5170V) was used; located on the flying deck forward railings. Flow rate = 1 m3/min. Aerosol_Sampler
Concentration of atmospheric aerosol total mercury (Hg) from R/V Knorr cruises KN199-04 and KN204-01 (GA03) in the Subtropical northern Atlantic Ocean from 2010-2011 (U.S. GEOTRACES NAT project)Aerosols were collected by Tisch high-volume aerosol samplers. Aerosol Sampler
North African mineral dust composition from R/V Knorr cruises KN199-04, KN204-01 in the Subtropical northern Atlantic Ocean from 2010-2011 (U.S. GEOTRACES NAT project)Two high-volume Tisch Environmental (model 5170-VBL) aerosol samplers were used. Aerosol Sampler
Total aerosol trace metal concentrations from R/V Knorr cruises KN199-04 and KN204-01 in the Subtropical northern Atlantic Ocean from 2010-2011 (U.S. GEOTRACES NAT project)Two high-volume Tisch Environmental (model 5170-VBL) aerosol samplers were used. Aerosol Sampler
Beryllium-7 in aerosol from samples collected on R/V Knorr KN204-01 in the Subtropical northern Atlantic Ocean from November to December 2011Aerosol samples were obtained with a Tisch TE-5170V-BL high volume aerosol sampler, modified to collect 12 replicate samples on acid-washed 47mm diameter Whatman-41 (W-41) filters, using procedures of the US GEOTRACES aerosol program. Tisch TE-5170V-BL high volume aerosol sampler
Lead (Pb) isotopic ratios in lake water, river water, groundwater, and TSP samples collected in and around Lake Tahoe from 2006 to 2016Graseby Andersen TSP High Volume Sampler
Concentrations of acetate, formate, chloride, sulfate, and oxalate from total suspended particle (TSP) samples collected near Lake Tahoe from 2006 to 2009Graseby Andersen TSP High Volume Sampler
Concentrations of metals in total suspended particle (TSP) samples collected near Lake Tahoe from 2006 to 2009Graseby Andersen TSP High Volume Sampler
Concentrations of nutrients in total suspended particle (TSP) samples collected near Lake Tahoe from 2006 to 2009Graseby Andersen TSP High Volume Sampler
Trace metal concentrations of lake water, river water, and groundwater at Lake Tahoe from 2013 to 2016Graseby Andersen TSP High Volume Sampler
Major inorganic ions in Primary Marine Aerosols (PMA) generated from seawater collected near the BATS station during R/V Atlantic Explorer cruises AE2113 (July 2021) and AE2303 (January 2023)A Microorifice Uniform Deposit Impactor (MOUDI) sampler was used once during each cruise to collect a dichotomous PMA sample with two particle size fractions; a submicron fraction with particles sizes ranging from 10 µm in diameter. Microorifice Uniform Deposit Impactor (MOUDI) sampler
Arctic aerosol Be7 concentrations from the MOSAIC expedition on the R/V Polarstern in the Central Arctic Ocean from December 2019 to June 2020Tisch TE-5170V-BL high volume aerosol sampler
Total organic carbon content, total nitrogen content, and carbon isotope (13C and 14C) composition of atmospheric particulates from aerosol samples collected on the R/V Dong Fang Hong-3 in the western North Pacific from October to December 2019Aerosol samples were collected with portable aerosol particle samplers (model 2030, Qingdao LaoyingE nvironmental Technology Co.) with a filter size of 9 cm O.D. portable aerosol particle samplers
Nutrients and iron in shipboard aerosol and rain samples collected during R/V Hugh R. Sharp cruise HRS1414 in the Mid-Atlantic Bight and northern South-Atlantic Bight from July to August of 2014 (DANCE project)Tisch Series 235 high-volume aerosol sampler equipped with a cascade impactor. Tisch Series 235
Inorganic nitrogen content; and nitrate, ammonium, and oxygen isotope composition of atmospheric particulates collected on Changdao Island, China from September 22, 2019 to September 5, 2020High-volume aerosol sampler (model 2031, Qingdao Laoying Environmental Technology Co) operating at 1.0 m3 min -1 with 25 × 20 cm filters. model 2031, Qingdao Laoying Environmental Technology Co
Total organic carbon, total nitrogen content; and nitrate, ammonium and oxygen isotope composition of atmospheric particulates collected aboard R/V Dong Fang Hong-3 in the western North Pacific from October 31 to December 1, 2019.Portable aerosol particle samplers: aerosol samples were collected with portable aerosol particle samplers (model 2030, Qingdao Laoying Environmental Technology Co.) with a filter size of 9 cm O.D. Portable aerosol particle samplers - model 2030, Qingdao Laoying Environmental Technology Co.
Aerosol composition data of ion concentrations (ammonium, nitrate, nitrite, sodium, chloride, magnesium, calcium, potassium, sulfate); and ammonium and nitrate isotope (15N) of atmospheric particulates collected in Hawaii from March 2021 to August 2022High-volume aerosol sampler operating at 1,200 L min-1 with 25 × 20 cm filters.