Three runs of six open system mesocosms run with 15N tracer addition from (oyster reef N2O emission project) | Samples for POM, and sediment 15N and 13C were run on and elemental analyzer (EA) coupled to an IRMS.
| elemental analyzer (EA) |
Seawater properties and biogeochemical parameters of bottom boundary layer samples collected aboard the R/V Oceanus during ten cruises from 2017-2019 from the Oregon shelf and slope. | | ThermoQuest NC2500 |
Amino acid d13C values of diatoms, bacteria, and core M772-003-2 samples from the R/V Meteor (M77) in the Peruvian ocean margin from November to December 2008. | Interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK)
| PDZ Europa ANCA-GSL elemental analyzer |
Amino acid d13C values of Thalassiosira weissflogii of ten different treatments; collections from R/V Meteor M77 in the Peruvian ocean margin from November to December 2008. | Interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK)
| PDZ Europa ANCA-GSL elemental analyzer |
Amino acid isotopes from mussels along the California margin from 2009-2013 (Amino Acid Sediment 15N project) | Interfaced via a ConFlo III device with a ThermoFinnigan Delta Plus XP isotope ratio mass spectrometer (Thermo Fisher Scientific)
| Carlo Erba CHNS-O EA1108-elemental analyzer |
Fluorescence dissolved organic matter (fDOM) analysis of inhalant and exhalent water samples from sponges studied at an artificial reef off the coast of the Florida Keys, USA in August 2021 | A Thermo Flash 1000 series elemental analyzer was used for elemental analysis of GF/F filters.
| Thermo Flash 1000 |
Sediment geochemistry summary from push cores collected during HOV Alvin dives during the R/V Atlantis cruise AT37-06 in the Guaymas Basin from December 2016 | | ThermoFinnigan FlashEA 1112 series NC Soil Analyzer |
Atlantic sediment black carbon, total organic carbon, and stable carbon ratio (13C) values from samples collected using a multi-corer and box corer from multiple cruises throughout the Atlantic between 1994 and 2010 | Elementar Vario MICRO cube elemental analyzer coupled to an Isoprime100 isotope ratio-mass spectrometer (IR-MS)
| Elementar Vario MICRO cube |
Atlantic sediment black carbon, total organic carbon, and stable carbon ratio (13C) values from samples collected using a multi-corer and box corer from multiple cruises throughout the Atlantic between 1994 and 2010 | Carlo Erba elemental analyzer coupled to a GV Optima 588 system IR-MS
| Carlo Erba elemental analyzer |
Mean d15N of individual amino acids and bulk organic matter for five plankton size fractions | Interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK)
| PDZ Europa ANCA-GSL elemental analyzer |
Particulate data collected near Friday Harbor, WA between 2020 and 2021 as part of a study of cold-water coral Balanophyllia elegans diet and trophic position | | Costech Elemental Analyzer |
Isotopes from B. gymnorhiza mangroves in Palau during 2013 | Paired with a Isotope-ratio Mass Spectrometer for leaf water and xylem water analysis
| Temperature Conversion Elemental Analyzer (TC/EA) |
Determination of carbon, nitrogen, and phosphorus content in sinking particles at the Bermuda Atlantic Time-series Study (BATS) site from December 1988 to June 2024 using a Particle Interceptor Trap System (PITS) | An Exeter Analytical CE440 Elemental Analyzer was use to measured the carbon and nitrogen present in the sediment trap flux samples. For information on operation of this instrument, refer to: http://www.exeteranalytical.co.uk/theory-of-operation/
| Exeter Analytical CE440 Elemental Analyzer |
Seawater biogeochemistry inshore and offshore the Bermuda coral reef from the Bermuda coral reef platform and adjacent Sargasso Sea extending to Bermuda Atlantic Time Series-station from 2014-2018 | Exeter Analytical Elemental Analyzer for POC and PON.
| Exeter Analytical Elemental Analyzer |
Biodiversity experiments: Effects of diversity in feeding trials, conducted at Bodgea Marine Laboratory, using detritus from eelgrass (Zostera marina) genotypes (clones) as a food source and either one or a combination of invertebrate grazers | Carbon and nitrogen concentrations were measured on a Thermo Flash EA 1112 Soil elemental analyzer.
| Thermo Flash EA 1112 Soil elemental analyzer |
Biogeochemical and microbial parameters collected during spatial surveys on a coral reef at Mo'orea's North Shore (French Polynesia) in September 2017, May 2019, and April 2022 | | Exeter Analytical CE 440 Elemental Analyzer |
All discrete TA/DIC samples from 2008-2012 collected from Bowdoin Buoy Mooring in the Lower Harpswell Sound, Casco Bay, Maine from 2011-2012 | DIC of unfiltered water was determined using an automated analyzer built by Apollo SciTech (Bogart, GA). (More information: http://www.apolloscitech.com/DIC.htm)
| DIC Automated Analyzer |
Bulk Carbon and Nitrogen isotopes from sperm whale dentin from the UC-Santa Cruz labs of P. Koch and M. McCarthy (Sperm Whale SI Ratios project) | These samples were analyzed for bulk delta-13C and delta-15N values in the Stable Isotope Lab at University of California at Santa Cruz on a EA 1108 elemental analyzer (Carlo Erba, Milan, Italy) coupled to a Thermo Finnigan DeltaPlus XP isotope ratio mass spectrometer (Thermo Scientific, Bremen, Germany).
| |
Bulk and CSIA-AA stable isotopes in sinking POM (sediment trap collected) and proteinaceous deep-sea coral skeletal material in Monterey Bay from 1998 to 2007 | Bulk isotope analysis was performed at the UC Santa Cruz Light Stable Isotope Laboratory using a Carlo Erba 1108 elemental analyzer coupled to Thermo Finnigan Delta Plux XP isotope ratio mass spectrometer following standard procedures (https://websites.pmc.ucsc.edu/~silab/index.php).
| Carlo Erba 1108 |
Bulk raw isotopic data from tissue samples from pelagic fish from R/V Kilo Moana cruise KM1123 in the north and west of the island of O'ahu in 2011 | Bulk sample nitrogen (N) and carbon (C) isotope compositions of all fishes were determined using an isotope ratio mass spectrometer (IRMS; Delta PlusXP) coupled to an elemental analyzer (Conflo IV/Costech ECS 4010).
| elemental analyzer |
Bulk raw isotopic data from tissue samples from non-tuna species collected in the eastern tropical Pacific Ocean onboard two NOAA research ships, David Starr Jordan and McArthur II, (cruises SWFSC1630 and SWFSC1631) in 2006 | Stable isotope values of nitrogen were determined using an on-line carbon-nitrogen analyzer coupled with an isotope ratio mass spectrometer (FinniganConFlo II/Delta-Plus).
| Carbon-Nitrogen Analyzer |
Bulk raw isotopic data from tissue samples from three species of tunas collected in the eastern tropical Pacific Ocean onboard commercial tuna purse-seine vessels from 2003-2005 | Stable isotope values of nitrogen were determined using an on-line carbon-nitrogen analyzer coupled with an isotope ratio mass spectrometer (FinniganConFlo II/Delta-Plus).
| Carbon-Nitrogen Analyzer |
Raw sediment C isotope values collected in Massachusetts from 2012 to 2015 | Used for analysis
| 1108 Elemental analyzer |
Carbon and nitrogen data from kelp determined during seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp species | Dried tissue was analyzed for nitrogen content and δ13C values by the UCSC Stable Isotope Laboratory using a CE Instruments NC2500 elemental analyzer coupled to a Thermo Scientific DELTAplus XP isotope ratio mass spectrometer via a Thermo-Scientific Conflo III.
| CE Instruments NC2500 |
Carbon flux for the Caribbean giant barrel sponge Xestospongia muta (Sponge-loop) | Used to measure POC
| CE Elantech NC2100 elemental analyzer |
Carbon flux for the Caribbean giant barrel sponge Xestospongia muta (Sponge-loop) | Used to measure DOC
| Shimadzu TOC 5050 analyzer |
Flux of organic carbon for sponges at Conch Reef, Key Largo, FL, and Carrie Bow Cay, Belize as sampled in 2016. | | CE Elantech NC2100 combustion elemental analyzer |
Carbon geochemistry of Santa Elena (Costa Rica) ultramafics and bulk rock carbonate samples from expeditions 149, 173, and 209 on R/V JOIDES Resolution in the Iberia Abyssal Plain, Iberian Margin, and Mid-Atlantic Ridge from 1993-2003 | TC contents, d13CTC and d13CTOC were determined on a Vario ISOTOPE elemental analyzer (EA) coupled to an Isoprime 100 isotope ratio mass spectrometer (IRMS).
| Vario ISOTOPE elemental analyzer |
P17N Ocean Acidification Pteropod Study: Carbonate chemistry system and hydrography samples from R/V New Horizon NH1208 from a transect 35-50 degrees North, Pacific Ocean, Aug-Sep 2012 (OAPS project) | Apollo SciTech DIC auto-analyzer (Model AS-C3). The analyzer acidifies each sample and the total CO2 is purged and then measured using a LI 7000 infrared analyzer.
| |
Table 1: Experimental conditions and fluid carbonate chemistry for RPI-3 run where only aragonite precipitated | Used to measure concentrations of ions.
| |
Elemental and isoptopic composition of sediment and biomass from the Carpinteria Salt March sampled in 2020 and 2021 | Elementar vario ISOTOPE select elemental analyzer interfaced to a Nu Horizon isotope ratio mass spectrometer to measure CNS and δ13C
| Elementar vario ISOTOPE select elemental analyzer interfaced to a Nu Horizon isotope ratio mass spectrometer |
Microbial cell abundance and carbon, nitrogen, and sulfur content from venting fluids and microbial mats at Axial Seamount; from R/V Atlantis cruise AT18-08 in the Axial Seamount, Juan de Fuca Ridge in 2011 | Bulk carbon and nitrogen were measured using a Thermo Scientific CN Analyzer (Model Flash 2000).
| Thermo Scientific CN Analyzer |
Microbial cell abundance and carbon, nitrogen, and sulfur content from venting fluids and microbial mats at Axial Seamount; from R/V Atlantis cruise AT18-08 in the Axial Seamount, Juan de Fuca Ridge in 2011 | Bulk sulfur was measured using a LECO S632 Sulfur Analyzer.
| LECO S632 Sulfur Analyzer |
Chemical data associated with field collections from the Gulf of Maine, Nauset Marsh Estuary System, and Long Island Sound (Alexandrium isotopes project) | Used to perform isotope analysis of NH4+ and POM
| Carlo Erba NC 2500 Elemental Analyzer (Model 1108) |
Closed Oyster Mesocosm 15N Tracer (Oyster Reef N2O Emission project) | Sediment 15N Phyto sample was analyzed on the IRMS coupled to a Costech Elemental Analyzer.
| Costech Elemental Analyzer |
Solid phase measurements of sediment cores from the Cocos Ridge (Eastern Equatorial Pacific) acquired during cruise SR2113 between November - December 2021. | Elemental Analyzer (EA, Costech) coupled to a Picarro Cavity Ring-Down Spectrometer (G2131-i) was used to measure Total Carbon
| Elemental Analyzer (EA, Costech) |
Controls run during remineralization experiments from R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
| An EA-IRMS with a Costech elemental analyzer (Valencia, CA, USA) coupled to a Thermo Scientific Delta XP Plus isotope ratio mass spectrometer (Bremen, Germany) was used to measure Bulk δ13C, δ15N, and mass percent Carbon and Nitrogen.
| Elemental Analyzer – Isotope Ratio Mass Spectrometry (EA-IRMS) System |
Experimental coral physiological and δ15N isotopic measurements in October 2012 at Reef Systems Coral Farm, Ohio. | A. millepora δ15N samples measured on Costech elemental analyzer coupled to a Thermo Finnigan Delta IV stable isotope ratio mass spectrometer (EA-SIRMS).
| Costech elemental analyzer |
Experimental coral physiological and δ15N isotopic measurements in October 2012 at Reef Systems Coral Farm, Ohio. | T. reniformis δ15N samples measured on Elementar Vario EL Cube/Micro Cube elemental analyzer interfaced to a PDZ Europa 20-20 stable isotope ratio mass spectrometer (EA-SIRMS).
| Elementar Vario EL Cube/Micro Cube elemental analyzer |
Physiological parameters of eight corals species surveyed from six locations around O'ahu, HI from August to November of 2015 | All isotope samples were combusted using a PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK) at the University of California Davis Stable Isotope Facility.
| PDZ Europa 20-20 isotope ratio mass spectrometer |
Carbon and nitrogen stable isotopes of Hawaiian corals collected from August to November 2015 | All samples were combusted using a PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK) at the University of California (UC) Davis Stable Isotope Facility
| PDZ Europa ANCA-GSL elemental analyzer |
Physiological measurements during Cyanobacteria Crocosphaera iron/warming experiments | 4010 Costech Elemental Analyzer
| 4010 Costech Elemental Analyzer |
CSIA-AA comparison between live polyps and outer proteinaceous skeletal material in three taxons of North Pacific deep-sea corals | For bulk isotopes:
Carlo Erba 1108 elemental analyzer interfaced to a Thermo Finnegan Delta Plus XP isotope ratio mass spectrometer.
| Carlo Erba 1108 elemental analyzer |
N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms, demonstrating new HPLC protocol for precise isotopic measurements | EA-IRMS analysis was conducted in the UCSC shared Stable Isotope Laboratory facility (UCSC-SIL), using an EA-IRMS analyzer dedicated to smaller samples. This system uses a Carlo Erba CHNS-O EA1108-Elemental Analyzer, interfaced via a Thermo Finnigan Gasbench II device to a Thermo Finnigan Delta Plus XP isotope ratio mass spectrometer (Thermo Fisher Scientific).
| Carlo Erba CHNS-O EA1108-elemental analyzer |
d15N of size-fractionated particulate organic nitrogen (PON) from net tows in the Sargasso Sea at BATS and Hydro Station S | The d15N of tow-collected, size-fractionated PON was determined by elemental analyzer-isotope ratio mass spectrometry (an Elementar Vario Isotope Cube online to an Elementar Isoprime visION), referencing to atmospheric N2 using USGS-40 and an in-house aminocaproic acid standard.
| Elementar Vario Isotope Cube |
[DRAFT] The biomass of turf samples in damselfish territory before and after treatment with fertilizer in Mo'orea, French Polynesia from June to July 2025 | Algal turf samples were analyzed with a continuous-flow isotope-ratio mass spectrometry interfaced to a CE Elantech NA2500 elemental analyzer.
| CE Elantech NA2500 elemental analyzer |
Molecular P characterization (by NMR) of initial dry POM added to each treatment from diatom samples collected on R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
Time-series of nutrient measurements following addition of diatom derived POM to seawater samples collected at Station ALOHA on R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
Dissolved organic matter sulfur and carbon analysis of samples collected between 2010 and 2021 from various locations globally | SPE extracts were analyzed for their C and S concentrations and stable isotope compositions (δ13C and δ34S) via combustion elemental analyzer (EA) / isotope ratio mass spectrometry (IRMS). The system comprised a Thermo Scientific Flash EA IsoLink CN, coupled to a Delta V Plus IRMS via a ConFlo IV Universal Interface. The EA was configured with dual columns (combustion: WO3 over Cu; reduction: Cu metal) and a temperature-programmable GC column oven that allows both CO2 and SO2 to be eluted in the same run, as described by Phillips et al. (2021). Due to the high C:S molar ratios of DOM, CO2 was diluted by 88.4% following combustion via the ConFlo. Urea standards were run at the same settings to account for any possible fractionation of 13C by this dilution.
| Thermo Scientific Flash EA IsoLink CN |
Doliolid abundance, carbon and nitrogen content, chlorophyll-a, temperature, salinity, and depth from CTD casts from 25 RV Savannah cruises at the South Atlantic Bight, 2015-2017 | Sample analysis for %C, %N , d13C and d15N were performed on a ThermoFisher Delta V plus isotope ratio mass spectrometer interfaced to a Thermo Flash Elemental analyzer.
| Thermo Flash Elemental analyzer |
Bacterial abundance, bacterial organic carbon, and total organic carbon from remineralization bioassays conducted on R/V Robert Gordon Sproul cruises along the Southern California coast during July and August 2023 | BOC samples were analyzed on a CCE-440 Elemental Analyzer (Exeter Analytics) calibrated with acetanilide standards.
| CCE-440 Elemental Analyzer |
Solid phase chemistry from gravity cores taken during R/V Atlantis cruise AT26-24 at the Dorado Outcrop near Cocos Ridge in December of 2014 (Dorado Outcrop project) | Carlo Erba NA-1500 elemental analyzer connected to a DeltaPlus XL mass spectrometer.
| Carlo Erba NA-1500 elemental analyzer |
Solid phase chemistry from gravity cores taken during R/V Atlantis cruise AT26-24 at the Dorado Outcrop near Cocos Ridge in December of 2014 (Dorado Outcrop project) | | Perkin Elmer Series II 2400 CHNS/O analyzer |
Solid phase chemistry from push cores taken during R/V Atlantis cruise AT26-24 at the Dorado Outcrop near Cocos Ridge in December of 2014 (Dorado Outcrop project) | Carlo Erba NA-1500 elemental analyzer connected to a DeltaPlus XL mass spectrometer.
| Carlo Erba NA-1500 elemental analyzer |
Solid phase chemistry from push cores taken during R/V Atlantis cruise AT26-24 at the Dorado Outcrop near Cocos Ridge in December of 2014 (Dorado Outcrop project) | | Perkin Elmer Series II 2400 CHNS/O analyzer |
Elemental stoichiometry for Emiliania huxleyi across a range of 12 temperatures from 8.5-28.6C | Used to measure organic/inorganic carbon and nitrogen.
| 440 elemental analyzer (Costech Inc., CA) |
Intracellular elemental quotas under low and high temperatures for E. huxleyi in constant and fluctuating thermal environments | Used to measure organic/inorganic carbon and nitrogen.
| 440 elemental analyzer (Costech Inc., CA) |
Extracted chlorophyll data, particulate carbon and nitrogen, flow cytometry and 15N2/13C rate measurements collected during EN596 from April 2017 in the North Atlantic | Organic carbon and total nitrogen content was analyzed using high-temperature combustion (1020 C) on a ThermoQuest NC 2500 elemental analyzer.
| ThermoQuest NC 2500 elemental analyzer |
Measurements of Chlorophyll, NO2, NO3, PO4, Silicate, NH4, PIC, POC, PON, BSi from CTD casts on R/V Endeavor cruise EN616 in July 2018 | | Perkin Elmer 2400 Series II CHNS/O |
Results from feeding assays conducted as part of seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp species | Dried tissue was analyzed for nitrogen content and δ13C values by the UCSC Stable Isotope Laboratory using a CE Instruments NC2500 elemental analyzer coupled to a Thermo Scientific DELTAplus XP isotope ratio mass spectrometer via a Thermo-Scientific Conflo III.
| CE Instruments NC2500 |
Feeding trials: Effects of diversity in feeding trials, conducted at Bodgea Marine Laboratory, using detritus from eelgrass (Zostera marina) genotypes (clones) as a food source and either one or a combination of invertebrate grazers | Carbon and nitrogen concentrations were measured on a Thermo Flash EA 1112 Soil elemental analyzer.
| Thermo Flash EA 1112 Soil elemental analyzer |
DRAFT Fertilizer impacts on damselfish behavior in Mo'orea | Samples were analyzed with continuous-flow isotope ratio mass spectrometry using a Micromass Optima interfaced to a CE Elantech NA2500 elemental analyzer.
| CE Elantech NA2500 elemental analyzer |
Hydrologic data from field sampling sites in the Neuse River Estuary, Pamlico Sound, and Onslow Bay in the coastal North Atlantic, offshore from North Carolina, USA, in 2021 and 2022 | | PE 2400 Series II CHNS/O Analyzer |
Body stoichiometry of coral reef fishes collected from the Indo-Pacific in 2016-2017 | Ground samples were analyzed for %P using dry oxidation-acid hydrolysis extraction followed by a colorometric analysis (Aplkem RF300).
| Aplkem RF300 |
Geochemical measurements of porewater from sediment push core samples in the Gulf of California during R/V Falkor cruise FK190211 in 2019 | | ThermoFinnigan FlashEA 1112 series NC Soil Analyzer |
Dissolved inorganic nitrogen, dissolved organic carbon, and chloropyll-a from the Middle Keys of Florida Bay during 2017-2018, following the passage of Hurricane Irma | | Spectrophotometric Elemental Analysis System (SEAS) |
Location, weathering, bulk isotope, and 14C data for fossil seals from the western Ross Sea, Antarctica from from 2013-2014 | This analysis was performed at the Stable Isotope Lab (SIL) at the University of California (UC) Santa Cruz on a Carlo Erba EA 1108 elemental analyzer coupled to a Thermo-Finnigan DeltaPlus XP isotope ratio mass spectrometer.
| EA-IRMS |
Elemental composition for 16S rRNA gene amplicon and metagenomic sequences collected on the R/V JOIDES Resolution (JRES-204) cruise in the Cascadia Continental Margin during 2002 (Methane-Hydrate Sediment Omics project) | PE 2400 CN(S) analyzer
| |
Size-fractionated major and minor particle composition and concentration from the US GEOTRACES Arctic cruise (HLY1502) on USCGC Healy from August to October 2015 | Used to analyze the following measured parameters: POC & PN; and the following derived parameters: POM
| CE Instruments NC2500 |
POM concentrations for carbon, nitrogen, and phosphorus from GO-SHIP Line I07N RB1803 in the Western Indian Ocean from April to June 2018 (Ocean Stoichiometry Project) | Samples analyzed at UCI were packed into tin packets alongside Atropine (C17H23NO3) standards (ranging from 0.2-1.5 mg) and measured using a Flash EA elemental analyzer.
| CN FlashEA 1112 Elemental Analyzer (Thermo Scientific, Waltham, Massachusetts) |
Size-fractionated major, minor, & trace particle composition and concentration from Leg 1 (Seattle, WA to Hilo, HI) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1814) on R/V Roger Revelle from Sept to Oct 2018 | Used in the measurement of POC and PN, and to derive POM.
| CE Instruments NC2500 |
Size-fractionated major, minor, & trace particle composition and concentration from Leg 2 (Hilo, HI to Papeete, French Polynesia) of the US GEOTRACES Pacific Meridional Transect (PMT) cruise (GP15, RR1815) on R/V Roger Revelle from Oct to Nov 2018 | Used in the measurement of POC and PN, and to derive POM.
| CE Instruments NC2500 |
Size-fractionated major and minor particle composition and concentration collected from RV Thompson (TN303) along the US GEOTRACES EPZT transect in the Eastern Tropical Pacific during 2013 (US GEOTRACES EPZT project) | Measured POC and PN
| Carlo Erba 1108 or a CE Instruments NC2500 elemental analyzer |
Grazing experiment 4: Carbon and Nitrogen data for low-high pCO2 acclimated Rhodomonas sp. cultures (E Hux Response to pCO2 project) | Measured carbon and nitrogen composition: Micro Cube elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer at the UC Davis Stable Isotope Facility.
| MICRO cube elemental analyzer |
Grazing experiment 5: Carbon and Nitrogen data for low-high pCO2 acclimated Rhodomonas sp. cultures (E Hux Response to pCO2 project) | Used to measure carbon and nitrogen concentrations
| Micro Cube elemental analyzer |
Grazing experiment 6: Carbon and Nitrogen data for low-high pCO2 acclimated Rhodomonas sp. cultures (E Hux Response to pCO2 project) | Used to measure carbon and nitrogen concentrations
| Micro Cube elemental analyzer |
Grazing experiment 7: Carbon and Nitrogen data for low-high pCO2 acclimated Rhodomonas sp. cultures (E Hux Response to pCO2 project) | Used to measure carbon and nitrogen concentrations
| Micro Cube elemental analyzer |
Growth rates, bulk isotope values, elemental composition data from the R/V Meteor M77 cruise in the Peruvian ocean margin from November to December 2008. | Interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK)
| PDZ Europa ANCA-GSL elemental analyzer |
Organic carbon and water soluble organic carbon atmospheric loadings from aerosol samples from R/V Knorr GEOTRACES cruises KN199-04 and KN204-01 in the Subtropical northern Atlantic Ocean in 2010 and 2011 | | CE Elantech Flash EA 1112 |
Organic matter C:N ratios from sediment cores collected on the Guaymas Basin Ridge flanks and the Sonora Margin from R/V El Puma during October 2014 | | Carlo Erba 1108 elemental analyzer |
delta 13C values from sediment cores collected on the Guaymas Basin Ridge flanks and the Sonora Margin from R/V El Puma during October 2014 | | Carlo Erba 1108 elemental analyzer |
delta 15N values from sediment cores collected on the Guaymas Basin Ridge flanks and the Sonora Margin from R/V El Puma during October 2014 | | Carlo Erba 1108 elemental analyzer |
TOC concentrations from sediment cores collected on the Guaymas Basin Ridge flanks and the Sonora Margin from R/V El Puma during October 2014 | Sediment samples were run on a Carlo Erba 1108 elemental analyzer with a Costech zero-blank autosampler (Costech Analytical Technologies, Inc., USA) interfaced to a Thermo Finnigan Delta Plus XP IRMS (Thermo Finnigan, USA).
| Carlo Erba 1108 elemental analyzer |
Ammonium uptake from short-term 6-hour deckboard incubations on R/V Nancy Foster cruises NF1704 and NF1802 in the Gulf of Mexico in May of 2017 and 2018 | PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK). C/N and isotopic analysis at the UC Davis stable isotope facility.
| PDZ Europa ANCA-GSL elemental analyzer |
Nitrate uptake from short-term 6-hour deckboard incubations on R/V Nancy Foster cruises NF1704 and NF1802 in the Gulf of Mexico in May of 2017 and 2018 | PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK). C/N and isotopic analysis at the UC Davis stable isotope facility.
| PDZ Europa ANCA-GSL elemental analyzer |
Ammonium uptake from short-term diel deckboard incubations on R/V Nancy Foster cruises NF1704 and NF1802 in the Gulf of Mexico in May of 2017 and 2018 | PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK). C/N and isotopic analysis at the UC Davis stable isotope facility.
| PDZ Europa ANCA-GSL elemental analyzer |
Nitrate uptake from short-term diel deckboard incubations on R/V Nancy Foster cruises NF1704 and NF1802 in the Gulf of Mexico in May of 2017 and 2018 | PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK). C/N and isotopic analysis at the UC Davis stable isotope facility.
| PDZ Europa ANCA-GSL elemental analyzer |
Nitrate uptake from in-situ incubations conducted during R/V Nancy Foster cruises NF1704 and NF1802 in the Gulf of Mexico in May of 2017 and 2018 | PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK). C/N and isotopic analysis at the UC Davis stable isotope facility.
| PDZ Europa ANCA-GSL elemental analyzer |
Net primary production by H13CO3- uptake from in-situ incubations conducted during R/V Nancy Foster cruises NF1704 and NF1802 in the Gulf of Maine in May of 2017 and 2018 | PDZ Europa ANCA-GSL elemental analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK). C/N and isotopic analysis at the UC Davis stable isotope facility.
| PDZ Europa ANCA-GSL elemental analyzer |
Particulate organic matter and isotope data from R/V Nancy Foster cruises NF1704 and NF1802 in the Gulf of Mexico in May of 2017 and 2018. | Elementar Vario EL Cube or Micro Cube elemental analyzer (Elementar Analysensysteme GmbH, Hanau, Germany) interfaced to either an Isoprime VisION IRMS (Elementar UK Ltd, Cheadle, UK) or a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK)
| |
Sample log for HADESK bacterial biomarker phospholipid fatty acid content from sediment cores collected on R/V Thomas G. Thompson cruise TN309, May 2014 | | Fisons NA 1500 elemental analyzer |
HADES-K CN concentrations and ratios and d13C bacterial biomass signatures in Kermadec Trench during RV/Thompson cruise TN309, May 2014 | | Fisons NA 1500 elemental analyzer |
Averages and standard deviation across species for all macrofauna found on each carbonate rock collected during R/V Atlantis cruise AT37-13 in the Pacific margin of Costa Rica from May to June 2017 | Stable isotopes measurements (d13C and d15N) were carried out using a Costech elemental analyzer coupled to a Micromass Iso-prime isotope ratio mass spectrometer (EA/IRMS) at Washington State University.
| Costech elemental analyzer |
High and low molecular weight (HMW, LMW) DOC 14C collected from the North Pacific Subtropical Gyre and Central North Atlantic | | Carlo Erba CHNS-O EA1108-elemental analyzer |
Water geochemistry from surface samples collected along the Neuse River, Neuse River Estuary, and Pamlico Sound in North Carolina between October and December 2016, following the passage of Hurricane Matthew | POC & PN. Calibrated with acetanilide.
| Thermo Scientific FlashEA 1112 Nitrogen and Carbon analyzer |
Chemical analyses of size-fractionated particle samples collected during the BIOS-SCOPE cruise AE1819 in the Sargasso Sea in July 2018 | Thermo Flash elemental analyzer coupled to a Conflo IV and MAT 253 Plus isotope ratio mass spectrometer (EA-IRMS, Thermo Scientific)
| Thermo Flash elemental analyzer |
TPC, PIC, POC, TPN, and Th-234 from in-situ pumps at the Porcupine Abyssal Plain Sustained Observatory (PAP-SO) site in the Northeast Atlantic Ocean during RRS Discovery cruise DY077 in April of 2017 | | Thermo Electron FlashEA 1112 C/N analyzer |
Microbial cell abundance,carbon fixation rates, and nitrate concentrations during shipboard incubations of vent fluids at the diffuse-flow vent Crab Spa, East Pacific Rise on RV/Atlantis cruise AT37-12, May 2017 | Used for carbon fixation measurements
| • Fisons 1108 Elemental Analyzer equipped with a Costech "Zero Blank" sample carousel |
Microbial cell abundance,carbon fixation rates, and nitrate concentrations during shipboard incubations of vent fluids at the diffuse-flow vent Crab Spa, East Pacific Rise on RV/Atlantis cruise AT37-12, May 2017 | Used to generate chromatographs from the photodetector and thus measure nitrate concentrations.
| Teledyne T200 NOx analyzer with a SRI Model 333 Peak Simple Chromatography Data System |
Inorganic carbon data from R/V Melville, R/V Roger Revelle MV1101, RR1202 cruises MV1101, RR1202 in the Southern Ocean (30-60S); 2011-2012 (Great Calcite Belt project) | DIC was determined using a high precision (0.05%CV) small-volume DIC analyzer (~1.5 ml sample size) using an infrared-based instrument (AIRICA; Marianda Co., Germany; Bates et al., 2012) with replicate samples analyzed using a VINDTA 3C system at BIOS.
VINDTA 3C
The VINDTA 3C (Versatile INstrument for the Determination of Total inorganic carbon and titration Alkalinity) combines the proven VINDTA alkalinity titration concept with a simplified extraction unit for coulometric dissolved inorganic carbon (DIC) measurement.
| VINDTA 3C |
Invertebrate survival: Invertebrate survival rates from feeding experiments, conducted at Bodega Marine Laboratory, where food sources (eelgrass (Zostera marina) genotypes) were varied | Carbon and nitrogen concentrations were measured on a Thermo Flash EA 1112 Soil elemental analyzer.
| Thermo Flash EA 1112 Soil elemental analyzer |
Description and isotopic composition of the carbonate deposits in the Santa Elena Ophiolite (Costa Rica) and expeditions 149, 173, and 209 on R/V JOIDES Resolution in the Iberia Abyssal Plain, Iberian Margin, and Mid-Atlantic Ridge from 1993-2003 | TC contents, d13CTC and d13CTOC were determined on a Vario ISOTOPE elemental analyzer (EA) coupled to an Isoprime 100 isotope ratio mass spectrometer (IRMS).
| Vario ISOTOPE elemental analyzer |
Kelp growth data from seasonal global change experiments examining the effects of seasonal variation in light availability and nutrients on the response of three high-latitude kelp species | Dried tissue was analyzed for nitrogen content and δ13C values by the UCSC Stable Isotope Laboratory using a CE Instruments NC2500 elemental analyzer coupled to a Thermo Scientific DELTAplus XP isotope ratio mass spectrometer via a Thermo-Scientific Conflo III.
| CE Instruments NC2500 |
Killed controls run during remineralization experiments from R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
POM concentrations for carbon, nitrogen, and phosphorus from GO-SHIP Line C13.5/A13.5 in 2020 | | CN FlashEA 1112 Elemental Analyzer (Thermo Scientific, Waltham, Massachusetts) |
POM concentrations for carbon, nitrogen, phosphorus, and chemical oxygen from GO-SHIP Line P18 Legs 1 and 2 in 2016 and 2017 | | CN FlashEA 1112 Elemental Analyzer (Thermo Scientific, Waltham, Massachusetts) |
Isotopes (d11B, 87Sr/86Sr, d18O, d13C), elemental concentrations (B, Mg, Ca), and carbon content collected from the foraminifera Ammonia parkinsoniana and sediments in Celestun Lagoon, Yucatan, Mexico in June 2009 and May 2015 | | Carlo Erba elemental analyzer IRMS |
Measured and calculated geochemistry values and uncertainty for water samples taken from the water column of Celestun Lagoon, Yucatan, Mexico in May of 2015 | | Carlo Erba elemental analyzer IRMS |
Macroalgal carbon and nitrogen data collected as part of macroalgal surveys in Sitka Sound, Alaska kelp beds from 2018 to 2020 | CE Instruments NC2500 elemental analyzer coupled to a Thermo Scientific DELTAplus XP isotope ratio mass spectrometer via a Thermo-Scientific Conflo III (routine measurement error ≤ 1.0 %C and ≤ 0.2 %N).
| CE Instruments NC2500 |
Concentration of inorganic nutrients, primary productivity measurements and phytoplankton cell concentration in seawater samples from the Malaspina 2010 Circumnavigation Expedition (VitaMaps project) | Metal concentrations were analyzed as described in [25] using a Thermo Element 2 HR-ICP-MS.
| Thermo Element 2 HR-ICP-MS |
Results of stable isotope analysis (C, N) of the posteriorly regenerated muscle tissue of Diopatra from the Georgia and South Carolina coasts in 2013 (Gracilaria effects project) | Thermo Flash EA
| |
Amino acid compound specific isotope values for micronekton from R/V Kilo Moana KM1109, KM1123, KM1407, KM1418, and other cruises in the Central North Pacific, Station ALOHA, Tropical Pacific, 2007-2014 | Used to measure carbon and nitrogen isotopic compositions.
| Costech Model 4010 |
C and N isotope data for Ross, Weddell, and crabeater seal tissues from west Antarctica collected during multiple field seasons from 2008-2010 | This analysis was performed at the Stable Isotope Lab (SIL) of UC Santa Cruz on a Carlo Erba EA 1108 elemental analyzer coupled to a Thermo-Finnigan DeltaPlus XP isotope ratio mass spectrometer.
| Carlo Erba EA 1108 elemental analyzer |
N isotopic composition of Phenylalanine and Glutamic Acid from a number of organisms, demonstrating new HPLC protocol for precise isotopic measurements | EA-IRMS analysis was conducted in the UCSC shared Stable Isotope Laboratory facility (UCSC-SIL), using an EA-IRMS analyzer dedicated to smaller samples. This system uses a Carlo Erba CHNS-O EA1108-Elemental Analyzer, interfaced via a Thermo Finnigan Gasbench II device to a Thermo Finnigan Delta Plus XP isotope ratio mass spectrometer (Thermo Fisher Scientific).
| Carlo Erba CHNS-O EA1108-elemental analyzer |
Organic carbon, carbonate, and opal data from Multitracers sediment trap samples | | elemental analyzer |
Carbon and nitrogen flux measurements from the Sargasso Sea from 2013-2014. | Used to measure TC and TN
| Combustion Elemental Analyzer |
Time-series Niskin-bottle sample data from R/V Hermano Gines cruises in the Cariaco Basin from 1995 through 2017 (CARIACO Ocean Time-Series Program) | Measurement: The filters were folded inside a tin disk and analyzed on a Perkin Elmer 2400 Elemental Analyzer. The samples were combusted at 1200-1300°C and then passed through a reduction tube to removes the oxygen added to raise the combustion temperature. Filers were not acid fumed prior to analysis. The C and N were then separated in a chromatographic column and were measured on a Thermal Conductivity Detector. Carbon and nitrogen standards, and blank filters were used to calibrate the data. The accuracy of the instrument was | Perkin Elmer 2400 Elemental Analyzer. |
Nitrogen and carbon fixation rates and POC and PON from thermal variation experiment of Trichodesmium GBR strain from 2016-2018 | Used to measure elemental ratios of POC and PON.
| Costech Elemental Analyzer ECS4010 CHNSO ANALYZER |
Nitrogen isotope fractionation for ammonium assimilation by marine phytoplankton (Biological Nitrogen Isotope Fractionation project) | Combustion of PON samples to produce dinitrogen gas for N isotope analyses, with calibration achieved using L-glutamic acid references USGS-40 and USGS-41.
| Costech ECS 4010 Elemental Analyzer coupled with Thermo Delta V isotope ratio mass spectrometer |
Total organic carbon content, total nitrogen content, and carbon isotope (13C and 14C) composition of atmospheric particulates from aerosol samples collected on the R/V Dong Fang Hong-3 in the western North Pacific from October to December 2019 | The concentrations of POC and TN were measured using an elemental analyzer (Elementar vario Isotope select).
| Elementar vario Isotope select |
Response of Bathycoccus sp. to iron-limitation sampled aboard R/V Roger Revelle RR1813 in the Subarctic North Pacific near Station PAPA (50 N, 144.8 W) from August to September 2018 | | |
Data on how nutrient and sediment loading affect coral functionality in a tropical branching coral | | Control Equipment Corporation: Model CEC 440HA |
Sediment C isotope ratios from incubations amended with 13C-labeled substrates from samples collected on cruise OC1703A aboard R/V Oceanus and cruise AT36 aboard R/V Atlantis | | Elementar Vario EL Cube or Micro Cube elemental analyzer |
Sediment N isotope ratios from incubations amended with 15N-labeled substrates from samples collected on cruise OC1703A aboard R/V Oceanus and cruise AT36 aboard R/V Atlantis | | Elementar Vario EL Cube or Micro Cube elemental analyzer |
Open Mesocosm Oyster 15N2 and N2O | 15N Phyto sample was analyzed on the IRMS coupled to a Costech Elemental Analyzer.
| Costech Elemental Analyzer |
Time-series of nutrient measurements following addition of POM collected off the coast of Oregon to seawater samples collected on R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
Organic carbon, d13C, and total nitrogen content of pelagic sediment from the North Atlantic gyre, South Pacific gyre, and Peru Basin from cruises KN223, KNOX02RR, and ODP leg 201 between 2002 and 2013 | Carlo Erba Elemental Analyzer Model 1108 and Finnegan-MAT DeltaPlus isotope ratio monitoring mass spectrometer. The instrument was calibrated and data drift-corrected with USGS-40 (L-glutamic acid) reference material and an in-house glycine standard.
| Carlo Erba Elemental Analyzer Model 1108 |
Cluster (combined temperature, nutrient concentration, and CO2) results from laboratory experiments with Pseudo-nitzschia australis conducted from 2021 to 2022 | | Costech 4010 Elemental Analyzer |
CO2 experiment physiology and carbonate chemistry from laboratory experiments with Pseudo-nitzschia australis conducted from 2021 to 2022 | | Costech 4010 Elemental Analyzer |
N:P ratio experiment physiology and carbonate chemistry laboratory experiments with Pseudo-nitzschia australis conducted from 2021 to 2022 | | Costech 4010 Elemental Analyzer |
Single-factor temperature experiment physiology and carbonate chemistry from laboratory experiments with Pseudo-nitzschia australis conducted from 2021 to 2022 | | Costech 4010 Elemental Analyzer |
Biochemistry of 3 pacific oyster cohorts from Whiskey Creek Hatchery in Netarts Bay, OR, USA from 2009-2011 | The remaining sample material was then analyzed by flash combustion (>1000 degrees C) using a Carlo Erba NA 1500 elemental analyzer interfaced by continuous-flow mass spectrometer (Delta-Plus XL).
| Carlo Erba NA 1500 |
Carbonate chemistry of 3 pacific oyster cohorts from Whiskey Creek Hatchery in Netarts Bay, OR, USA from 2009-2011 | The remaining sample material was then analyzed by flash combustion (>1000 degrees C) using a Carlo Erba NA 1500 elemental analyzer interfaced by continuous-flow mass spectrometer (Delta-Plus XL).
| Carlo Erba NA 1500 |
Stable isotopes of 3 pacific oyster cohorts from Whiskey Creek Hatchery in Netarts Bay, OR, USA from 2009-2011 | The remaining sample material was then analyzed by flash combustion (>1000 degrees C) using a Carlo Erba NA 1500 elemental analyzer interfaced by continuous-flow mass spectrometer (Delta-Plus XL).
| Carlo Erba NA 1500 |
Particulate organic carbon, nitrogen, and Thorium-234 collected during the 2012-2013 Palmer Field Season (WAP Carbon export project) | After subsequent background counts using the RISO low-level beta multi-counter, samples were acidified to remove calcium carbonate and analyzed for carbon and nitrogen on an elemental analyzer.
| Elemental Analyzer |
Size Fractionated Particulate Thorium-234 measurements collected during the 2012-2013 Palmer Field Season | Sea water samples were acidified to remove CaCO3 and analyzed in an elemental analyzer to determine particulate organic carbon and particulate nitrogen on filters.
| Elemental analyzer |
Particle bulk d15N values from EXPORTS cruises SR1812 on R/V Sally Ride and RR1813 on R/V Roger Revelle in August to September 2018 | | Thermo Fisher Scientific Flash Elemental Analyzer (EA) |
Particulate Carbon Concentrations and Stable Carbon Isotopes in Marine Particles Captured by In Situ Mclane Pumps at Cocos Ridge Coco Ridge (Eastern Equatorial Pacific) during cruise SR2113 between November - December 2021 | | Elemental Analyzer (Costech) |
Particulate organic carbon and particulate nitrogen from samples collected on R/V Nathaniel B. Palmer cruise NBP1910 along the Western Antarctic Peninsula from November to December 2019 | | CEC440 Elemental Analyzer |
Concentrations of particulate organic matter (POC, PON, POP, PCOD), total oxygen demand, POM ratios, and respiration ratios from samples collected on R/V Atlantic Explorer BATS validation study #58 in the Sargasso Sea in October 2021 | | Thermo Scientific FlashEA 1112 |
| A Costech ECS 4010 Elemental Analyzer coupled with a Thermo Delta V isotope ratio mass spectrometer was used for the combustion of PON samples to produce dinitrogen gas for N isotope analyses, with calibration achieved using L-glutamic acid references USGS-40 and USGS-41.
| Costech ECS 4010 Elemental Analyzer |
Data on phytoplankton physiology and iron and temperature interactions collected in the Ross Sea during 2013 (Ross Sea Microb Ecophys project) | 440 Elemental Analyzer (Costech Inc, Valencia, CA)
| |
Animal condition data from Pleuromamma xiphias (Atlantic Ocean, AMT24) (Plankton Population Genetics project) | Used to measure the C and N content of the copepods
| Costech elemental combustion system (Model 4010) |
Particulate organic carbon from the formation fluids recovered from the CORKs installed at North Pond; collected on Maria S. Merian cruise MSM20-5 in 2012 | The dried filters were then transferred into a tin capsule before placing within a high temperature combustion CN elemental analyzer (Costech, ECS 4010) connected in-line with a Mass Spectrometer (ThermoFinnigan Delta XP interfaced with a ConFloIV) for analysis of their organic carbon and nitrogen isotopic compositions.
| Costech, ECS 4010 |
Particulate organic matter (PON, POC, POP) concentrations collected on R/V Roger Revelle cruise RR1604 along the hydrographic line IO9 in the Eastern Indian Ocean from March to April 2016 | CN FlashEA 1112 Elemental Analyzer (Thermo Scientific, Waltham, Massachusetts)
| CN FlashEA 1112 Elemental Analyzer |
Time-series of nutrient measurements following addition of Prochlorococcus derived POM to seawater samples collected at Station ALOHA on R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
Data resulting from testing dilution experiments conducted in the development of four assays to quantify copeod naupliar biomass in Kaneohe Bay, Hawaii | Exeter Analytical CE 440 was used for CHN analysis of copepods.
| Exeter Analytical CE 440 |
Measurements of mixed field samples used for qPCR estimates and estimating biomass of DNA copy number in bulk samples | Exeter Analytical CE 440 was used for CHN analysis of copepods.
| Exeter Analytical CE 440 |
Measurements of individual body size and qPCR estimates of DNA copy number per individual from the development of four assays to quantify copeod naupliar biomass in Kaneohe Bay, Hawaii | Exeter Analytical CE 440 was used for CHN analysis of copepods.
| Exeter Analytical CE 440 |
Reference carbon and nitrogen concentrations, and isotope ratios from alfalfa, nylon-6, bovine liver, and enriched alanine | Used for chemical and isotope analyses.
| PDZ Europa ANCA-GSL elemental analyzer |
CTD-associated variables, bottle salinity measurements, oxygen titrations, nutrient analyses, biogeochemical/biological variables, and DIC/Freon chemistry variables from R/V Roger Revelle cruise RR2004 along the 150W meridian from 30S to 60S | | Perkin Elmer 2400 Series II CHNS/O |
Bulk N2 fixation measurements from UCYN-A symbiosis in the Southern California Current System from May 2017 (SP1714) and October (SP1724) SCCS cruises. | Samples for bulk PON/POC and N2 fixation and CO2 fixation rates were measured on an Elemental Combustion System (Costech Analytical Technologies) interfaced to a Thermo Finnigan Delta V Advantage isotope ratio mass spectrometer (Thermo Fisher Scientific) at the SOEST Biogeochemical Stable Isotope Facility at the University of Hawai’i, Manoa.
| Elemental Combustion System (Costech Analytical Technologies) |
Carbon, nitrogen and their isotope composition of eelgrass from Virginia Coastal Lagoons and turtlegrass from St George Sound FL | Used for chemical and isotope analyses.
| PDZ Europa ANCA-GSL elemental analyzer |
Nutrient content and stable isotope ratios from seagrasses in Texas over one year following Hurricane Harvey | | Thermo Fisher Scientific Flash EA-Isolink CNSOH elemental analyzer |
Summary of carbon and nitrogen concentrations and isotope ratios from samples of eelgrass from Virginia Coastal Lagoons and turtlegrass from St George Sound FL | Used for chemical and isotope analyses.
| PDZ Europa ANCA-GSL elemental analyzer |
N2O, 15N2, 15N tissue tracer in oyster aquariums (Oyster Reef N2O Emission project) | Oyster tissue 15N was analyzed via IRMS coupled to a Costech Elemental Analyzer.
| Costech Elemental Analyzer |
Geochemical composition of sediment samples collected in the Equatorial Pacific during October and November 2020 on R/V Kilo Moana cruise KM2012 | | GVI (now Elementar) Isoprime 1000 |
Geochemical composition of sediment pore water samples collected in the Equatorial Pacific during October and November 2020 on R/V Kilo Moana cruise KM2012 | | GVI (now Elementar) Isoprime 1000 |
Sediment core porewater and particulate measurements from three sites on the Louisiana Shelf sampled during R/V Pelican cruises from December 2021 through August 2022 | Samples measured at University of California Davis were run on an elemental analyzer interfaced to a continuous flow isotope ratio mass spectrometer. See Stable Isotope Facility instrument descriptions here: https://stableisotopefacility.ucdavis.edu
| Elemental analyzer at UC Davis |
Sediment core porewater and particulate measurements from three sites on the Louisiana Shelf sampled during R/V Pelican cruises in August 2021 | Samples measured at University of California Davis were run on an elemental analyzer interfaced to a continuous flow isotope ratio mass spectrometer. See Stable Isotope Facility instrument descriptions here: https://stableisotopefacility.ucdavis.edu
| Elemental analyzer at UC Davis |
Carbon, Nitrogen, biogenic silica, thorium-234, and mass fluxes from upper ocean sediment traps at the Porcupine Abyssal Plain Sustained Observatory (PAP-SO) site in the Northeast Atlantic Ocean during RRS Discovery cruise DY077 in April of 2017 | | Thermo Electron FlashEA 1112 C/N analyzer |
Sinking PIC, PC in shallow sediment traps collected along a North Pacific transect between Hawaii and Alaska on R/V Kilo Moana cruise KM1712 in August 2017 | Total Particulate Carbon (PC) and Particulate Nitrogen (PN) were analyzed by burning a subsample of the GFF on Elemental Analyzer (EA).
| Costech ECS4010 CHNSO Elemental Analyzer |
Concentrations of dissolved inorganic macronutrients, chlorophyll a, phaeophytin, PON, and POC measured during phytoplankton shipboard incubation experiments on the FeOA cruise SKQ202209S on R/V Sikuliaq in the NE Pacific from June to July 2022 | Thermo Delta V plus Continuous Flow Elemental Analyzer Isotope Ratio Mass Spectrometer coupled to a Thermo Flash Elemental Analyzer for POC, PON, 15N, 13C analyses of incubation samples.
| Thermo Flash Elemental Analyzer |
Shotgun Proteomics of Pseudonitzschia multiseries Multi stress incubations. | | Thermo Flash 2000 CHN Elemental Analyser |
Sinking particle from R/V Kilo Moana cruise KM1910 in June 2019 | A Vario ISOTOPE select (Elementar Isoprime) was used to quantify total C, N, and d13C and d15N. Samples are combusted/reduced at high temperature to create gases (CO2 and N2); column chromatography separates the gases; a thermal conductivity detector determines the carbon and nitrogen concentrations, followed by an isotope ratio mass spectrometer for bulk isotope composition. Measurements were calibrated with an in-house aminocaproic acid standard (ACROS) and four USGS standards (#41, #41a, #65, #25). Analytical uncertainty (determined from standards with similar isotope values) was 0.2‰ for delta-15N and 0.1‰ for delta-13C.
| Elementar Isoprime |
Bulk stable isotopes from siphonophores collected during four research cruises on the R/V Wester Flyer in the California Current Ecosystem between 2019 and 2021 | For bulk stable isotope analysis, siphonophore samples were analyzed using a Costech (Valencia, CA, USA) elemental combustion system coupled to a Thermo-Finnigan Delta XP isotope ratio mass spectrometer with N2 standard for nitrogen and Vienna Pee Dee Belemnite for carbon.
| Costech (Valencia, CA, USA) elemental combustion system |
Size fractionated zooplankton C:N, d13C, and d15N from the EXPORTS cruise on R/V Roger Revelle (RR1813) during August and September 2018 | Costech Model 4010 elemental combustion system
| Costech Model 4010 |
Soil physicochemical properties of coastal wetland soil cores collected in June 2018 from Barataria Bay, Louisiana | %C and %N were determined using a Vario Micro Cube CHNS Analyzer on dried, ground subsamples.
| Vario Micro Cube CHNS Analyzer |
Stable Isotope Data for Invertebrates Collected from Southern California Seeps in May and August 2021 | Elemental analyzer interfaced to a continuous flow isotope ratio mass.
| |
Planktic foraminifer tissue and shell d15N from net tows on R/V S.A. Agulhas II cruises VOY016 and VOY019 in the Southern Ocean south of Africa during 2015-2016 | | Thermo Scientific FLASH 2000 |
Bulk suspended PON d15N from several cruises conducted in the Southern Ocean south of Africa from 2012-2019 | | Thermo Scientific FLASH 2000 elemental analyzer |
Size-fractionated zooplankton d15N from net tows on R/V S.A. Agulhas II cruises VOY016 and VOY019 in the Southern Ocean south of Africa during 2015-2016 | | Thermo Scientific FLASH 2000 elemental analyzer |
Microbial Symbionts, Carbon, and Nutrient Cycling in Caribbean Coral Reef Sponges from Conch Reef, Key Largo (Florida, USA) and Carrie Bow Cay (Belize) in June and July 2016 | | CE Elantech NC2100 Elemental Analyzer |
Carbon and nitrogen isotope data from zooplankton and fish larvae collected on the SR2114 expedition in the Eastern Tropical North Pacific aboard the R/V Sally Ride from December 2021 to January 2022 | Carbon and nitrogen isotope ratios were measured at the Boston University Stable Isotope Laboratory using a GV Instruments IsoPrime isotope ratio mass spectrometer coupled with an elemental analyzer.
| elemental analyzer |
Stable carbon isotopic composition of organic matter from seafloor basalts incubated with labeled bicarbonate from R/V Atlantis AT15-51, R/V Kilo Moana KM0923, and Maria S. Merian MSM20-5 cruises | Dried samples of basalt (20–70 mg) were placed into tin foil capsules for isotopic analysis of 13C/12C ratios. Samples were analyzed using a Costech elemental analyzer in line with a Micromass Isoprime continuous flow stable isotope mass spectrometer.
| Costech elemental analyzer |
Isotopic analysis of ¹³C and ¹⁵N for sponges, coral, and zooxanthellae (family Symbiodiniaceae) used in a 'pulse-chase' experiment to examine the uptake of sponge-derived nutrients by the coral holobiont | | Europa ANCA-SL elemental analyzer |
Carbon and Nitrogen stable isotope measurements for experimental animals used in laboratory-based experiments collected from the Gulf of Mexico Estuary near Port Aransas, Texas from 2020 to 2022 | ThermoFisher Scientific Delta V isotope ratio mass spectrometer (IRMS) coupled to a ThermoFisher Scientific EA-Isolink CNSOH element analyzer.
| ThermoFisher Scientific EA-Isolink CNSOH element analyzer |
Carbon and Nitrogen stable isotope measurements for various marine samples collected from the Gulf of Mexico as well as eggs, animals, and food sources collected in the laboratory and commercial sources from 2020 to 2022. | ThermoFisher Scientific Delta V isotope ratio mass spectrometer (IRMS) coupled to a ThermoFisher Scientific EA-Isolink CNSOH element analyzer.
| ThermoFisher Scientific EA-Isolink CNSOH element analyzer. |
The acetate and inorganic carbon uptake rates as determined via stable isotopic tracers from Maria S. Merian cruise MSM20-5 in 2012; data generated using the formation fluids recovered from CORKs installed at North Pond | Filters were weighed into tin capsules and analyzed for 13C/ 12C ratios with an automated Isotope Cube elemental analyzer (Elementar, Germany) interfaced to a Delta Advantage isotope ratio mass spectrometer (Thermo, Germany).
| Isotope Cube elemental analyzer |
C and N stable isotopes and elemental ratios of high and low molecular weight (HMW, LMW) DOM collected from the North Pacific Subtropical Gyre and Central North Atlantic determined by elemental analyzer isotope ratio mass spectrometry (EA-IRMS) | | Carlo Erba CHNS-O EA1108-elemental analyzer |
Dissolved black carbon (DBC) concentrations and related data from water samples collected between 2011 and 2019 in the Pacific and Atlantic Oceans and from rivers in North America, South America, Africa, and Russia | Thermo Scientific Flash EA Isolink CNSOH interfaced with a Thermo Scientific Delta V Plus IRMS – To measure stable carbon isotopic values of SPE-DOC for all samples.
| Thermo Scientific Flash EA Isolink |
Observational and experimental stable isotope data including stable isotopes from infauna collected in sediment cores at McMurdo Station, Antarctica in September, November and February of 2012 and 2013 (McMurdo Benthos project) | Isotopic analysis was measured on a Eurovector elemental analyzer interfaced with a continuous flow Micromass Isoprime isotope ratio mass spectrometer (irms) at Washington State University.
| Eurovector elemental analyzer |
Sulfur geochemistry of the Santa Elena (Costa Rica) ultramafics; R/V JOIDES Resolution JRES-149, JRES-173, JRES-209 cruises in the Iberia Abyssal Plain, Iberian Margin, and Mid-Atlantic Ridge from 1993-2003 | TC contents, d13CTC and d13CTOC were determined on a Vario ISOTOPE elemental analyzer (EA) coupled to an Isoprime 100 isotope ratio mass spectrometer (IRMS).
| Vario ISOTOPE elemental analyzer |
Suspended particles from in situ pumps on R/V Kilo Moana cruise KM1910 in June 2019 | A Vario ISOTOPE select (Elementar Isoprime) was used to quantify total C, N, and d13C and d15N. Samples are combusted/reduced at high temperature to create gases (CO2 and N2); column chromatography separates the gases; a thermal conductivity detector determines the carbon and nitrogen concentrations, followed by an isotope ratio mass spectrometer for bulk isotope composition. Measurements were calibrated with an in-house aminocaproic acid standard (ACROS) and four USGS standards (#41, #41a, #65, #25). Analytical uncertainty (determined from standards with natural abundance isotope values) was 0.2‰ for delta-15N and 0.1‰ for delta-13C.
| Vario ISOTOPE select (Elementar Isoprime) |
Suspended PIC, PC, PN data collected along a North Pacific transect between Hawaii and Alaska on R/V Kilo Moana cruise KM1712 in August 2017 | Total Particulate Carbon (PC) and Particulate Nitrogen (PN) were analyzed by burning a subsample of the GFF on Elemental Analyzer (EA).
| Costech ECS4010 CHNSO Elemental Analyzer |
Suspended particles from ship’s surface intake samples collected on R/V Kilo Moana cruise KM1910 in June 2019 | A Vario ISOTOPE select (Elementar Isoprime) was used to quantify total C, N, and d13C and d15N.
| EA-IRMS |
Synechococcus batch culture data (cell quotas and ratios (C,N,P), size, and diameter) from laboratory experiments in 2021 to 2022 with related isolates cultured across a range of temperatures (16-25C) | | Flash EA 1112 NC Soil Analyzer (Thermo-Scientific, MA) |
Synthesis Product for Ocean Time Series (SPOTS) |
Orion EA 940 Analyzer used by HOT & DYFAMED for Total Alkalinity measurements
Perkin Elmer 2400 Elemental Analyzer used by CARIACO for PIC and PON measurements
Exeter Analytical CE-440 CHN used by HOT for POC and PON measurements
| Elemental analyzer |
Total DOC 14C from samples collected from the North Pacific Subtropical Gyre and Central North Atlantic | | Carlo Erba CHNS-O EA1108-elemental analyzer |
Molecular P characterization (by NMR) of initial dry POM added to each treatment from Tricho samples collected on R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
Time-series of nutrient measurements following addition of Trichodesmium derived POM to seawater samples collected at Station ALOHA on R/V Kilo Moana cruise KM1110 in the North Pacific Subtropical Gyre in 2011 | A Carlo-Erba C/N Analyzer was used to determine particulate C (PC) and N (PN) content.
| Carlo-Erba C/N Analyzer |
Dissolved and sinking particulate organic nitrogen data from a large volume mesocosm experiment in the Noumea Lagoon, New Caledonia, measured from January to February 2013 | The d15N of PNsink was measured using a Thermo Scientific Flash 2000 Elemental Analyzer coupled with a Delta Plus Thermo Scientific mass spectrometer.
| Thermo Scientific Flash 2000 Elemental Analyzer |
Geochemical composition of water column samples collected in the Equatorial Pacific during October and November 2020 on R/V Kilo Moana cruise KM2012 | | GVI (now Elementar) Isoprime 1000 |
Weekly surface water samples from Newport Pier, CA collected between 11 January 2012 and 3 November 2023 | | FlashEA 1112 Analyzer; Thermo Scientific, Waltham, Massachusetts |
Inorganic nitrogen content; and nitrate, ammonium, and oxygen isotope composition of atmospheric particulates collected on Changdao Island, China from September 22, 2019 to September 5, 2020 | Elemental analyzer: the concentrations of TN were measured using an elemental analyzer (Elementar vario Isotope select).
| Elementar vario Isotope select |
Total organic carbon, total nitrogen content; and nitrate, ammonium and oxygen isotope composition of atmospheric particulates collected aboard R/V Dong Fang Hong-3 in the western North Pacific from October 31 to December 1, 2019. | Elemental analyzer: the concentrations of POC and TN were measured using an elemental analyzer (Elementar vario Isotope select).
| Elementar vario Isotope select |
Bulk stable isotopes (d13C, d15N) of size-fractionated zooplankton collected near the Chatham Rise on the R/V Tangaroa SalpPOOP (TAN1810) cruise in Oct. and Nov. of 2018 | Elementar Vario EL Cube or Micro Cube elemental analyzer (Elementar Analysensysteme GmbH, Hanau, Germany) interfaced to either an Isoprime VisION IRMS (Elementar UK Ltd, Cheadle, UK) or a PDZ Europa 20-20 isotope ratio mass spectrometer (Sercon Ltd., Cheshire, UK)
| Elementar Vario EL Cube or Micro Cube elemental analyzer (Elementar Analysensysteme GmbH, Hanau, Germany) |
[DEPRECATED] Averages and standard deviation of stable isotopes (d13C and d15N) across species for all macrofauna found on each substrate (carbonate rocks, woods, and bones) of the colonization experiment held in Mound 12 | Stable isotopes measurements (d13C and d15N) were carried out using a Costech elemental analyzer coupled to a Micromass Iso-prime isotope ratio mass spectrometer (EA/IRMS) at Washington State University.
| Costech elemental analyzer |
[DEPRECATED] Recovery parameters, isotopic composition, and elemental composition of HMW and LMW DOM collected in the North Pacific Subtropical Gyre on R/V Kilo Moana (KM1506, KM1515) during 2015 | Used to analyze 13C, 15N, and C/N
| Carlo Erba CHNS-O EA1108-elemental analyzer interfaced via a ConFlo III device |